Alpha Wire Alpha Essentials Communication & Control Series Control Cable, 1 Pairs, 0.56 mm², 30 m, Grey Sheath Polyvinyl

小計(1 卷,共 305 米)*

TWD16,000.00

(不含稅)

TWD16,800.00

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 19 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
每卷
每米*
1 +TWD16,000.00TWD52.459

* 參考價格

RS庫存編號:
277-3678
Distrelec 貨號:
300-99-356
製造零件編號:
1896/4C SL001
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Number of Pairs

1

Product Type

Control Cable

Cross Sectional Area

0.56 mm²

Cable Length

30m

Jacket Colour

Grey

Jacket Material

Polyvinyl Chloride

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

80°C

Standards/Approvals

UL AWM/STYLE 2509, California Proposition 65, EU 2011/65/EU(RoHS2), CSA International CMG, REACH Regulation (EC 1907/2006), EU Low Voltage 2014/35/EU, EU 2015/863/EU (RoHS3)

Fire Behaviour

FT4

Conductor Material

Tin Copper Wire

Series

Alpha Essentials Communication & Control

Voltage

300Vrms

豁免

Belden Alpha Essentials Communication & Control Series Control Cable, 30m Cable Length, 0.56mm² Cross Sectional Area - 1896/4C SL001


This control cable provides a flexible connection for communication and control systems in industrial environments. It is designed for general-purpose signal and control wiring where a compact, multi-conductor cable with a PVC outer sheath is required. The construction supports moderate mechanical handling while maintaining electrical continuity for single-pair control circuits.

Features & Benefits


• Tin-plated copper conductors reduce corrosion and maintain conductivity
• Seven-strand conductors deliver improved flexing capability
• 0.56mm² conductor cross section supports typical control currents
• PVC jacket rated FT4 for enhanced vertical flame performance
• Operating range from -20°C to 80°C for varied site conditions

**Applications**


• Suitable for factory automation control panels and wiring
• Ideal for industrial sensor and actuator interconnections
• Used with Terminal blocks and PLC input/output wiring
• Can be used for machine tool signal cabling in workshops

What conductor construction enables repeated flexing?


Each conductor comprises seven tinned copper strands, which increase flexibility compared with solid wire and help resist breakage under repeated movement.

How is the cable marked for identification during installation?


The jacket is printed with manufacturer and type information alongside temperature and safety designations to assist identification on site.

What electrical characteristic is relevant for design calculations?


The nominal conductor DC resistance is approximately 10.2 Ω per 1000 ft at 20°C, useful for voltage-drop assessments in long runs.

What mechanical limits should installers observe when routing?


Maintain a bend radius of at least 10x the cable diameter and avoid exceeding a pull tension of 35 lb during installation.

Which regulatory restrictions apply to material composition?


The cable conforms to RoHS and REACH requirements and follows regional low-voltage and flame-performance specifications as part of its declared compliance.