Alpha Wire Alpha Essentials LSZH Communication & Control Series Data Cable, 2 Pairs, 0.35 mm², 305 m, Slate Sheath Low

小計(1 卷,共 305 米)*

TWD17,446.00

(不含稅)

TWD18,318.30

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 1,525 件從 2026年7月07日 起裝運發貨
  • 加上 2,135 件從 2026年7月14日 起發貨
  • 加上 1,830 件從 2026年7月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
每卷*
305 +TWD57.20TWD17,446.00

* 參考價格

RS庫存編號:
187-2075
製造零件編號:
1173L SL001
製造商:
Alpha Wire
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Alpha Wire

Number of Pairs

2

Product Type

Data Cable

Cross Sectional Area

0.35mm²

Cable Length

305m

Jacket Colour

Slate

Outside Diameter

4.27mm

Minimum Operating Temperature

-20°C

Conductor Type

Copper

Jacket Material

Low Smoke Zero Halogen

Maximum Operating Temperature

75°C

Standards/Approvals

UL, CSA, CE

Fire Behaviour

Low Smoke Zero Halogen (LSZH)

Series

Alpha Essentials LSZH Communication & Control

Voltage

300V

Conductor Material

Tin Copper Wire

Core Strands

7

Belden Alpha Essentials LSZH Communication & Control Series Data Cable, 305m Cable Length, Slate Jacket - 1173L SL001


This data cable is a two-pair LSZH communication cable designed for controlled-environment signal and control runs in automation, electronics and electrical installations. It combines tin-plated multi-strand copper conductors with a low smoke zero halogen outer sheath to provide a compact, low-emission option for installations requiring moderate temperature operation.

Features & Benefits


• 0.35mm² tin copper conductors for corrosion resistance and flexibility
• 7-strand conductor construction for improved bend performance
• 300V rating for use in low-voltage control circuits
• Low smoke zero halogen jacket to limit toxic gas and corrosive residues
• 75°C maximum operating temperature for elevated ambient conditions

**Applications**


• Suitable for control-panel interconnects in factory automation
• Ideal for sensor and actuator wiring in machinery systems
• Used with building management and signalling circuits
• Can be used for internal wiring of electrical cabinets

What conductor construction assists routing through confined ducts?


The conductor comprises seven tinned copper strands per core, providing increased flexibility for tight bends and easier cable pulling.

How does the cable perform in fire-restricted environments?


The sheath formulation produces reduced smoke and minimal acid gas when exposed to flame, meeting relevant IEC tests for smoke and acid gas generation.

What packing options are available for site installation?


Standard continuous lengths include 100 ft, 500 ft and 1,000 ft reels, with bulk made-to-order options for larger projects.

What mechanical limitations should installers note during pulling?


Maintain a minimum bend radius of ten times the cable diameter and keep pull tensions below the specified maximum to avoid conductor damage.

How does the cable meet international acceptance for projects?


It carries recognised safety approvals and meets EU RoHS and REACH substance restrictions, supporting specification in multi-jurisdiction installations.