SICK RE27 Safety Switch Actuator Included, Vistal, Magnet

小計(1 件)*

TWD5,068.00

(不含稅)

TWD5,321.40

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年2月01日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,068.00

* 參考價格

RS庫存編號:
285-2282
製造零件編號:
RE27-SA20L
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Safety Switch

Lock Type

Magnet

Actuator Included

Yes

Housing Material

Vistal

Series

RE27

Contact AC Voltage

230V ac

IP Rating

IP67

Minimum Operating Temperature

-30°C

Contact DC Voltage

24V dc

Maximum Operating Temperature

60°C

Hazardous Area Certification

No

Width

25mm

Length

88mm

Standards/Approvals

IEC 60529

Number of Head Directions

3

Depth

13mm

COO (Country of Origin):
MY

SICK RE27 Series Safety Switch, IP67, VISTAL Housing - RE27-SA20L


This safety switch is a non-contact magnetic sensor system designed to secure access points in industrial machinery. It operates with reed-type outputs and a separate actuator included, providing a monitored Interface for safety logic units. The device is suitable for environments requiring sealed protection and performs across a wide ambient temperature range while signalling status via LEDs.

Features and Benefits:


• IEC60529 protection provides dust and water resistance
• Reed contact outputs support low-voltage signalling
• 20m cable enables remote connection to control units
• Magnet lock type ensures contactless actuation
• Multi-directional head offers versatile approach angles

Applications


• Suitable for guarding hinged safety doors on production lines
• Ideal for integration with safety controllers in packaging plants
• Used with conveyors where sealed sensors are required
• Can be used for access monitoring in wet environments
• Suitable for installations demanding long cable runs

What electrical voltages can the device switch?


It switches up to 30V DC on reed contacts and is rated for 230V AC contact operation with 24V DC signalling circuits.

How is fault behaviour handled if an internal error occurs?


The unit lacks internal fault detection and relies on the connected safety-related logic unit for fault monitoring and safe-state determination.

What mechanical approvals and robustness standards does it meet?


The enclosure is rated to IP67 per IEC60529 and it meets vibration and shock levels defined in EN 60947-5-3.

What are the operating temperature limits for storage and use?


The device operates and may be stored within the same range of -30°C to +60°C.

How many signalling and auxiliary contacts are provided?


It provides two N/O contacts and one signalling contact configured for status indication via an LED.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。