ABB F200 RCD, 25A, 4 Pole, 30mA, Type AC, 230/400V ac
- RS庫存編號:
- 183-3636
- 製造零件編號:
- 2CSF204023R1250
- 製造商:
- ABB
小計(1 件)*
TWD3,888.00
(不含稅)
TWD4,082.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 11 件從 2026年2月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,888.00 |
* 參考價格
- RS庫存編號:
- 183-3636
- 製造零件編號:
- 2CSF204023R1250
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Circuit Breaker Type | RCCB | |
| Current Rating | 25A | |
| Number of Poles | 4 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type AC | |
| Voltage Rating | 230/400V ac | |
| Series | F200 | |
| Standards Met | IEC/EN 61008-1, IEC/EN 61008-2-1 | |
| Earth Leakage Protection Type | Type AC | |
| Overall Length | 69mm | |
| Break Time | Instantaneous | |
| Mounting Style | DIN Rail Mount | |
| Breaking Capacity at Maximum Voltage Rating | 1 kA | |
| Overall Dimensions | 70 x 69 x 85mm | |
| Reset Actuator Type | Toggle Switch | |
| Special Features | Protection Against Indirect Contacts and Additional Protection Against Direct Contacts, Protection Against the Effects of Sinusoidal Alternating Earth Fault Currents | |
| Rated AC Voltage | 230/400V | |
| Overall Depth | 85mm | |
| Terminal Contact Type | Screw | |
| Overall Width | 70mm | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Circuit Breaker Type RCCB | ||
Current Rating 25A | ||
Number of Poles 4 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type AC | ||
Voltage Rating 230/400V ac | ||
Series F200 | ||
Standards Met IEC/EN 61008-1, IEC/EN 61008-2-1 | ||
Earth Leakage Protection Type Type AC | ||
Overall Length 69mm | ||
Break Time Instantaneous | ||
Mounting Style DIN Rail Mount | ||
Breaking Capacity at Maximum Voltage Rating 1 kA | ||
Overall Dimensions 70 x 69 x 85mm | ||
Reset Actuator Type Toggle Switch | ||
Special Features Protection Against Indirect Contacts and Additional Protection Against Direct Contacts, Protection Against the Effects of Sinusoidal Alternating Earth Fault Currents | ||
Rated AC Voltage 230/400V | ||
Overall Depth 85mm | ||
Terminal Contact Type Screw | ||
Overall Width 70mm | ||
- COO (Country of Origin):
- IT
ABB F200 Series RCD, 69mm Overall Length, DIN Rail Mount Mounting Style - 442041
This Residual Current Device (RCD) offers effective earth leakage protection, enhancing safety for both individuals and electrical installations. It is essential for electrical systems, mitigating potential hazards resulting from fault currents to earth. This device is particularly configured for applications where the neutral is positioned to the left, making it a suitable choice for various installation needs.
Features & Benefits
• Type AC circuit breaker protects against sinusoidal alternating faults
• 4-pole construction allows versatile application in three-phase systems
• Designed for DIN rail mounting for straightforward installation
• Rated for 30 mA sensitivity to improve user safety
• Sturdy design complies with IEC 61008 standards for dependability
• 4-pole construction allows versatile application in three-phase systems
• Designed for DIN rail mounting for straightforward installation
• Rated for 30 mA sensitivity to improve user safety
• Sturdy design complies with IEC 61008 standards for dependability
Applications
• Suitable for commercial electrical installations to meet safety regulations
• Appropriate for residential environments requiring enhanced earth protection
• Ideal for systems requiring left-positioned neutral terminals
• Suitable for where continuous power is essential
• Appropriate for residential environments requiring enhanced earth protection
• Ideal for systems requiring left-positioned neutral terminals
• Suitable for where continuous power is essential
What are the ambient temperature limits for operation?
The device functions effectively within a temperature range of -25°C to +55°C.
How does it handle fault currents?
The instantaneous tripping feature enables quick disconnection during fault conditions, minimising risk.
What type of connections does it utilise?
It employs screw terminals for secure and dependable electrical connections.
相關連結
- Hager CDC RCD Switch 4 Pole Type AC, 230 → 400V
- ABB F200 RCCB 2 Pole Type A, 230/400V ac
- ABB F200 RCCB 4 Pole Type A, 230/400V ac
- ABB F200 RCCB 4 Pole 400V ac
- ABB DDA 200 A RCD 3 Pole Type A, 230/400V ac
- Hager CDF RCD Switch 4 Pole Type F, 230 → 400V
- Hager CDB RCD Switch 4 Pole Type B, 230 → 400V
- Schneider Electric IKQ RCD 4 Pole 400V ac