- RS庫存編號:
- 176-9633
- 製造零件編號:
- F202F-40/0.03
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Circuit Breaker Type | RCCB | |
| Current Rating | 40A | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Voltage Rating | 230V ac | |
| Series | F200 | |
| Overall Depth | 85mm | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Overall Dimensions | 35 x 69 x 85mm | |
| Earth Leakage Protection Type | A-APR | |
| Reset Actuator Type | Toggle Switch | |
| Terminal Contact Type | Screw | |
| Mounting Style | DIN Rail Mount | |
| Special Features | Earth Fault Safety Protection | |
| Overall Length | 35mm | |
| Break Time | Time Delay | |
| Overall Width | 69mm | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Circuit Breaker Type RCCB | ||
Current Rating 40A | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Voltage Rating 230V ac | ||
Series F200 | ||
Overall Depth 85mm | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Dimensions 35 x 69 x 85mm | ||
Earth Leakage Protection Type A-APR | ||
Reset Actuator Type Toggle Switch | ||
Terminal Contact Type Screw | ||
Mounting Style DIN Rail Mount | ||
Special Features Earth Fault Safety Protection | ||
Overall Length 35mm | ||
Break Time Time Delay | ||
Overall Width 69mm | ||
- COO (Country of Origin):
- IT
F202 Type F, RCCB in two poles with rated current 25-40-63A and sensitivity 30mA for the protection of single phase circuits.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR
this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.