RS Better World

Siemens Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 2-Pole, 30 mA Trip Sensitivity,

小計(1 件)*

TWD6,120.00

(不含稅)

TWD6,426.00

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 4 件從 2026年7月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD6,120.00

* 參考價格

我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。

瞭解有關RS Better World產品的更多資訊

RS庫存編號:
196-3608
製造零件編號:
5SU13531KK10
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Current Rating

10A

Product Type

Residual Current Circuit Breaker with Overload Protection

Range

SENTRON

Series

5SU1

Number of Poles

2

Trip Sensitivity

30mA

Tripping Characteristics

Type AC

Mount Type

DIN Rail

Rated AC Voltage

230V ac

Earth Leakage Protection Type

AC

Width

36mm

Depth

77mm

Height

90mm

Better World Product

Yes

Better World Claim

Extended Product Life

Reset Actuator Type

Toggle Switch

Breaking Capacity

4.5kA

Standards/Approvals

CETerminal Contact Type

COO (Country of Origin):
RO

Siemens 5SU1 Series RCBO, 10A Current Rating, 30mA Trip Sensitivity - 5SU13531KK10


This RCBO is a reliable type AC circuit breaker, offering essential protection in electrical installations. With a current rating of 10A and a maximum breaking capacity of 4.5kA, this 2-pole device is designed for rapid tripping in the event of a fault. It measures 35.4mm in width, 76.2mm in height, and has a depth of 90mm, making it ideal for DIN rail mounting.

Features & Benefits


• Instantaneous trip reduces potential electrical hazards

• 30mA trip sensitivity protects against earth faults

• Easy installation with screw terminal connections

• Halogen-free construction promotes safety and sustainability

Applications


• Implemented in residential and commercial electrical panels

• Utilised in automation systems requiring circuit protection

• Suitable for industrial machinery and equipment safeguarding

• Employed in complex electrical installations for enhanced safety

How does the tripping characteristic class C benefit electrical systems?


The class C tripping characteristic is suitable for applications with moderate inrush currents, allowing the device to withstand brief overloads without tripping, thus supporting system reliability.

What is the significance of having a 2-pole configuration?


The 2-pole configuration provides simultaneous protection for both live and neutral conductors, ensuring comprehensive safety in dual-phase electrical systems, preventing issues such as imbalances or overloads.

Can this device handle higher surge currents?


Yes, this RCBO has a surge current resistance of 1kA at a rise time of (8/20) μs, allowing it to withstand brief high current surges typically associated with fault conditions.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。