Eaton Residual Current Circuit Breaker with Overload Protection, 16 A Current Rating, 1-Pole, 30 mA Trip Sensitivity,
- RS庫存編號:
- 183-3540
- Distrelec 貨號:
- 303-96-434
- 製造零件編號:
- 236948 PXK-B16/1N/003-A
- 製造商:
- Eaton
小計(1 件)*
TWD2,428.00
(不含稅)
TWD2,549.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 85 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD2,428.00 |
* 參考價格
- RS庫存編號:
- 183-3540
- Distrelec 貨號:
- 303-96-434
- 製造零件編號:
- 236948 PXK-B16/1N/003-A
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Current Rating | 16 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 1 | |
| Range | PXK | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 240 V | |
| Earth Leakage Protection Type | Type A | |
| Depth | 69.5mm | |
| Width | 2 mm | |
| Standards/Approvals | IEC/EN 61009 | |
| Breaking Capacity | 10kA | |
| Application | Commercial, Residential | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Current Rating 16 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 1 | ||
Range PXK | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Rated AC Voltage 240 V | ||
Earth Leakage Protection Type Type A | ||
Depth 69.5mm | ||
Width 2 mm | ||
Standards/Approvals IEC/EN 61009 | ||
Breaking Capacity 10kA | ||
Application Commercial, Residential | ||
- COO (Country of Origin):
- AT
Eaton RCD, 16 A, Type B - PXK-B Series - PXK-B16/1N/003-A
Protect yourself and your electrical equipment from short circuits, surges and current overload with this Eaton RCD (residual current device). When the breaker detects any current imbalances – which can indicate a serious shock hazard – it isolates the circuit and cuts off the electricity. This quick action prevents shocks to operators and damage to equipment. Attach a breaker to each circuit so that a fault in one won't stop the other circuits from functioning.
• Breaking capacity at maximum voltage rating of 10 kA for safety
• Current rating of 16 A and AC voltage of 240 V for versatile use
• Switchgear suitable for domestic and commercial application
How much current is needed to trip this circuit breaker?
A trip sensitivity of 30 mA and type B tripping mean it breaks at a current of 120 to 150 mA within 40 milliseconds. This rates as high sensitivity.
How does this circuit breaker detect current leakage?
This unit detects small stray voltages by measuring the current on the circuit's supply and return conductors. It also features Type-A earth leakage protection, meaning it breaks the circuit for sinusoidal and alternating residual currents along with pulsed, DC residual currents that reach dangerous levels, for greater safety.
Note
Eaton formerly known as Moeller
相關連結
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type C, PXK Range
- Eaton RCBO 1P+N Poles Type B, PXK Range
- Eaton RCBO 1P + N Poles Type B, xPole Range