Eaton Residual Current Circuit Breaker with Overload Protection, 32A Current Rating, 1-Pole, 30 mA Trip Sensitivity,

小計(1 件)*

TWD5,922.00

(不含稅)

TWD6,218.10

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 15 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD5,922.00

* 參考價格

RS庫存編號:
203-9037
製造零件編號:
236967 PXK-C32/1N/003-A
製造商:
Eaton
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Eaton

Current Rating

32A

Product Type

Residual Current Circuit Breaker with Overload Protection

Range

PXK

Series

PXK

Number of Poles

1

Trip Sensitivity

30mA

Tripping Characteristics

Type A, Type C

Mount Type

DIN Rail

Rated AC Voltage

240V ac

Terminal Type

Screw

Earth Leakage Protection Type

Type A

Depth

69.5mm

Height

75mm

Application

Residential, Commercial

Tripping Mechanism

Thermal Magnetic

Standards/Approvals

IEC/EN 61009, IEC/EN 61439

Breaking Capacity

10kA

COO (Country of Origin):
AT

Eaton RCD/MCB Combination Switch, 1+N Poles, Type A and Type C Trip - PXK Series - PXK-C32/1N/003-A


Use this reliable electrical combination switch from Eaton to protect operators and equipment against two types of faults. Its RCD (residual current device) functionality safeguards against earth leakages and electrical shocks, and it provides standard MCB (miniature circuit breaker) overcurrent protection against electrical overloads and short circuits. You can use this device on consumer units and mission-critical circuits to establish a safer environment and prevent nuisance trips.

• Combined type-A and type-C tripping characteristics ensure power supply disconnection when electrical current is two to three times the rated amount and when flow-through current is between five to 10 times the rated current

• DIN rail mounting capability to save space and offer easy installation in standard setups

Are all combination switches and RCBOs (residual current circuit breakers with overcurrent protection) double poled?


Most RCBOs are single-pole, meaning they have one pole and a neutral, which is usually indicated as 1P+N. Some models claim to be double-poled based on this parameter but are in fact single pole. If you want a double-pole RCBO, opt for a 2-module width.

Eaton Residual Current Circuit Breakers with Over-current Protection (RCBOs) - PXK Series


The PXK series of residual current breakers with over current protection (RCBOs) from Eaton protect against two types of fault by combining the functionality of an RCD & MCB into a single device. Providing standard residual current device (RCD) protection against earth leakage and electric shock whilst also providing standard miniature circuit breaker overcurrent protection in the form of electrical overloads and short circuits. As this RCBO device protects against both faults it can prevent nuisance trips and can be used on consumer units and mission critical circuits.

Features & Benefits


• RCD & MCB combination switch

• Single pole

• Sensitivity to pulse current

• Breaking Capacity of 10 kA

• Compatible with standard busbar

• IEC / EN 61439

• Min. Operating temperature: -25 ° C

• Max working temperature: +40 ° C

What are the differences between the Tripping Curves?


Type A: Instantaneous trip with the electrical current this 2 to 3 times the rated current. Type A RCBOs protect against special forms of residual pulsating DC which have not been smoothed.

Type B: Instantaneous trip when the electrical current through the device is 3 to 5 times the rated current. The type B curve RCBOs are designed for standard circuit protection, typically protection of generators, persons and very long cables.

Type C: Instantaneous trip when the flow-through current is 5 to 10 times the rated current. Type C curve residential and domestic RCBOs are used for higher inrush currents such as in machines and lighting, providing overload protection of circuits and other consumer units.

Type AC: A combination of both A and C types, type AC RCBOs are suited to both domestic appliances and devices sensitive to short circuit.

Note

Eaton formerly known as Moeller

相關連結