Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator

小計(1 件)*

TWD172,163.00

(不含稅)

TWD180,771.15

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 4 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD172,163.00

* 參考價格

RS庫存編號:
623-9901
製造零件編號:
FLUKE-718 1G
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Maximum Pressure Measurement

68.9mbar

Product Type

Pressure Calibrator

Battery Type

Alkaline

Accuracy

±0.025 %

Minimum Pressure Measurement

-68.9mbar

Resolution

0.001 mbar

Pressure Port Type

Gauge

Data Logging

No

Model Number

718

Intrinsically Safe

No

Display Type

LCD

Current Loop Measurement

Yes

Power Source

Battery

Weight

992g

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Battery Life

20h

Standards/Approvals

No

Width

94mm

Length

216mm

Height

66mm

Hazardous Area Certification

NO

豁免

Fluke Pressure Calibrator, ±0.025% Accuracy, 68.9 m Bar Maximum Pressure Measurement - FLUKE-718 1G


This handheld pressure calibrator provides a compact, portable solution for pressure transmitter, gauge and switch calibration in industrial settings. It combines a pressure source with milliamp measurement and an integrated pump designed for easy maintenance after exposure to process fluids, enabling on-site calibration and troubleshooting across automation, electrical, electronics and mechanical environments.

Features & Benefits


• Resolution 0.001 mbar improves fine low-pressure adjustments
• Accuracy ±0.025% delivers precise full-span measurements
• Battery powered pressure calibrator 20 h life supports long field shifts
• LCD pressure calibrator Alkaline battery simplifies status monitoring
• Maximum pressure measurement ±68.9 mbar covers low-pressure work
• Error percentage calculation speeds pass/fail decision making

**Applications**


• Suitable for calibrating pressure transmitters in process control systems
• Ideal for testing pressure switches on pneumatic control panels
• Used with pressure gauges during installation and commissioning checks
• Can be used for field loop checks with 4–20 mA devices
• Used for maintenance of HVAC and low-pressure instrumentation

What power source and battery arrangement does it use?


It runs from alkaline 9V batteries with two cells in the instrument and typical run time up to 20 h depending on functions used.

How does the pump handle accidental fluid exposure?


The pump features protective check valves and a removable valve assembly allowing field cleaning of springs and O-rings to remove residue without full disassembly.

What environmental conditions can it tolerate during operation?


It operates between -10 °C and 55 °C, withstands random vibration at 2 g from 5 Hz–500 Hz and survives a 1m drop test.

What simultaneous measurements are displayed?


The LCD shows five-digit pressure and current values at the same time for combined pressure and milliamp readings.

How Compact and portable is the instrument for site work?


The unit with holster measures 216mm x 94mm x 66mm and weighs 992 g for convenient handheld use.

Standards

CSA C22.2 no. 1010.1: 1992, IEC 61010, CAT I 30V

Supplied with

Fluke 718, holster, TL75 test leads, AC72 crocodile clips, two 9 V batteries, instruction manual