Fluke 718 -850 mbar to 7 bar Pressure Calibrator

可享批量折扣
查看批量定價選項

小計(1 件)*

TWD178,645.00

(不含稅)

TWD187,577.25

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。

單位
每單位
1 - 4TWD178,645.00
5 +TWD175,073.00

* 參考價格

RS庫存編號:
351-2815
製造零件編號:
FLUKE-718 100US/APAC
製造商:
Fluke
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Fluke

Product Type

Pressure Calibrator

Maximum Pressure Measurement

7bar

Battery Type

Alkaline

Minimum Pressure Measurement

-850mbar

Accuracy

±0.015 %

Resolution

0.1 mbar

Model Number

718

Data Logging

No

Display Type

LCD

Current Loop Measurement

Yes

Power Source

Battery

Weight

992g

Minimum Operating Temperature

-10°C

Battery Life

20h

Maximum Operating Temperature

55°C

Width

94mm

Standards/Approvals

No

Length

216mm

Height

66mm

Hazardous Area Certification

No

豁免

COO (Country of Origin):
CN

Fluke Pressure Calibrator, 7 Bar Maximum Pressure Measurement, ±0.015 % Accuracy - FLUKE-718 100


This pressure calibrator is a compact, battery-powered handheld instrument designed to generate and measure pneumatic pressure and to verify current loop signals for industrial calibration of transmitters, gauges and switches. It operates in field conditions between -10°C and 55°C and displays simultaneous pressure and current readings on an LCD for straightforward on-site diagnostics.

Features and Benefits:


• ±0.015% mA accuracy delivers precise current measurement
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks

Applications


• Suitable for calibrating pressure transmitters and gauges on-site
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance

What type of batteries does it use and how are they installed?


It uses alkaline 9 V batteries (ANSI/NEDA 1604A or IEC 6LR61) and requires two cells installed in the battery compartment.

How does the pump handle exposure to process fluids?


The pump includes protective check valves and a serviceable valve assembly that can be cleaned in the field using isopropyl alcohol and Basic tools.

What display information is available simultaneously during calibration?


The LCD shows five‑digit pressure and current readings at the same time for concurrent measurement review.

How does the unit perform switch testing?


A dedicated switch test function captures trip and reset points, aiding Faster and more accurate pressure switch assessments.

What environmental stresses can the instrument withstand during transport?


It tolerates a 1 m drop test and random vibration at 2 g across 5 Hz-500 Hz frequencies.

Supplied with

protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)