Fluke 718 -850 mbar to 7 bar Pressure Calibrator
- RS庫存編號:
- 351-2815
- 製造零件編號:
- FLUKE-718 100US/APAC
- 製造商:
- Fluke
可享批量折扣
查看批量定價選項小計(1 件)*
TWD178,645.00
(不含稅)
TWD187,577.25
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 4 | TWD178,645.00 |
| 5 + | TWD175,073.00 |
* 參考價格
- RS庫存編號:
- 351-2815
- 製造零件編號:
- FLUKE-718 100US/APAC
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Pressure Calibrator | |
| Maximum Pressure Measurement | 7bar | |
| Battery Type | Alkaline | |
| Minimum Pressure Measurement | -850mbar | |
| Accuracy | ±0.015 % | |
| Resolution | 0.1 mbar | |
| Model Number | 718 | |
| Data Logging | No | |
| Display Type | LCD | |
| Current Loop Measurement | Yes | |
| Power Source | Battery | |
| Weight | 992g | |
| Minimum Operating Temperature | -10°C | |
| Battery Life | 20h | |
| Maximum Operating Temperature | 55°C | |
| Width | 94mm | |
| Standards/Approvals | No | |
| Length | 216mm | |
| Height | 66mm | |
| Hazardous Area Certification | No | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Pressure Calibrator | ||
Maximum Pressure Measurement 7bar | ||
Battery Type Alkaline | ||
Minimum Pressure Measurement -850mbar | ||
Accuracy ±0.015 % | ||
Resolution 0.1 mbar | ||
Model Number 718 | ||
Data Logging No | ||
Display Type LCD | ||
Current Loop Measurement Yes | ||
Power Source Battery | ||
Weight 992g | ||
Minimum Operating Temperature -10°C | ||
Battery Life 20h | ||
Maximum Operating Temperature 55°C | ||
Width 94mm | ||
Standards/Approvals No | ||
Length 216mm | ||
Height 66mm | ||
Hazardous Area Certification No | ||
豁免
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, 7 Bar Maximum Pressure Measurement, ±0.015 % Accuracy - FLUKE-718 100
This pressure calibrator is a compact, battery-powered handheld instrument designed to generate and measure pneumatic pressure and to verify current loop signals for industrial calibration of transmitters, gauges and switches. It operates in field conditions between -10°C and 55°C and displays simultaneous pressure and current readings on an LCD for straightforward on-site diagnostics.
Features and Benefits:
• ±0.015% mA accuracy delivers precise current measurement
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
• 0.1 mbar resolution enables fine pressure discrimination
• -850 mbar to 7 bar range supports negative and positive pressures
• Battery powered with 20 h life reduces interruption in field work
• Current loop capability measures and drives 4-20 mA signals
• Lightweight 992 g construction improves portability during tasks
Applications
• Suitable for calibrating pressure transmitters and gauges on-site
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
• Used for testing pressure switches in process control systems
• Ideal for loop validation and 4-20 mA instrument checks
• Can be used for service work where Compact tools are required
• Used with non‑corrosive gases during routine maintenance
What type of batteries does it use and how are they installed?
It uses alkaline 9 V batteries (ANSI/NEDA 1604A or IEC 6LR61) and requires two cells installed in the battery compartment.
How does the pump handle exposure to process fluids?
The pump includes protective check valves and a serviceable valve assembly that can be cleaned in the field using isopropyl alcohol and Basic tools.
What display information is available simultaneously during calibration?
The LCD shows five‑digit pressure and current readings at the same time for concurrent measurement review.
How does the unit perform switch testing?
A dedicated switch test function captures trip and reset points, aiding Faster and more accurate pressure switch assessments.
What environmental stresses can the instrument withstand during transport?
It tolerates a 1 m drop test and random vibration at 2 g across 5 Hz-500 Hz frequencies.
Supplied with
protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)
相關連結
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 717 -850 mbar to 7 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20 bar Pressure Calibrator
- Fluke 719 -850 mbar to 8 bar Pressure Calibrator
- Fluke 719 -850 mbar to 2.4 bar Pressure Calibrator