Fluke 718 -850 mbar to 7 bar Pressure Calibrator
- RS庫存編號:
- 351-2815
- 製造零件編號:
- FLUKE-718 100US/APAC
- 製造商:
- Fluke
可享批量折扣
查看批量定價選項小計(1 件)*
TWD174,848.00
(不含稅)
TWD183,590.40
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年12月09日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 4 | TWD174,848.00 |
| 5 + | TWD171,352.00 |
* 參考價格
- RS庫存編號:
- 351-2815
- 製造零件編號:
- FLUKE-718 100US/APAC
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Battery Type | Alkaline | |
| Product Type | Pressure Calibrator | |
| Maximum Pressure Measurement | 7bar | |
| Accuracy | ±0.015 % | |
| Minimum Pressure Measurement | -850mbar | |
| Resolution | 0.1 mbar | |
| Model Number | 718 | |
| Data Logging | No | |
| Display Type | LCD | |
| Current Loop Measurement | Yes | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Maximum Operating Temperature | 55°C | |
| Battery Life | 20h | |
| Height | 66mm | |
| Width | 94mm | |
| Standards/Approvals | No | |
| Length | 216mm | |
| Hazardous Area Certification | No | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Battery Type Alkaline | ||
Product Type Pressure Calibrator | ||
Maximum Pressure Measurement 7bar | ||
Accuracy ±0.015 % | ||
Minimum Pressure Measurement -850mbar | ||
Resolution 0.1 mbar | ||
Model Number 718 | ||
Data Logging No | ||
Display Type LCD | ||
Current Loop Measurement Yes | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Maximum Operating Temperature 55°C | ||
Battery Life 20h | ||
Height 66mm | ||
Width 94mm | ||
Standards/Approvals No | ||
Length 216mm | ||
Hazardous Area Certification No | ||
豁免
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, ±0.015% Accuracy, 7 Bar Maximum Pressure Measurement - FLUKE-718 100
This pressure calibrator is a handheld instrument designed to provide a compact, battery-powered solution for calibrating transmitters, gauges and switches in field and workshop settings. It combines a pressure source with milliamp measurement capability and an integrated pump that resists fluid ingress, allowing technicians to generate and measure pressure while powering loop devices.
Features & Benefits
• ±0.015% mA accuracy for precise current loop verification
• Pressure range from -850 mbar to 7 bar for wide coverage
• High-resolution 0.1 mbar resolution for fine pressure discrimination
• LCD display showing simultaneous pressure and current readings
• Battery operation delivering up to 20 h typical use per set of batteries
• Integrated pump with serviceable valve assembly for field cleaning
• Pressure range from -850 mbar to 7 bar for wide coverage
• High-resolution 0.1 mbar resolution for fine pressure discrimination
• LCD display showing simultaneous pressure and current readings
• Battery operation delivering up to 20 h typical use per set of batteries
• Integrated pump with serviceable valve assembly for field cleaning
**Applications**
• Suitable for commissioning and calibrating pressure transmitters on site
• Ideal for testing and adjusting pressure switches in process systems
• Used for functional verification of gauges across -850 mbar to 7 bar
• Can be used for loop-powered sensor checks and mA calibration
• Used with non-corrosive gases for field pressure validation
• Ideal for testing and adjusting pressure switches in process systems
• Used for functional verification of gauges across -850 mbar to 7 bar
• Can be used for loop-powered sensor checks and mA calibration
• Used with non-corrosive gases for field pressure validation
What battery type does it use and how many are required?
It uses alkaline 9V cells and requires two batteries to power all functions.
How does the pump cope with accidental fluid exposure?
The pump features protective check valves and a removable valve assembly enabling in-field cleaning using isopropyl alcohol and simple tools.
What measurement capability exists for current loops?
It measures 0 mA–24 mA with 0.001 mA resolution and an accuracy of 0.015%+1 count and can drive 20 mA into 1000 Ω when battery voltage exceeds 6.8 V.
Which pressure units and ranges are supported via the built-in pump?
The instrument supports multiple units including psi, bar, mbar, kPa, inH2O and mmHg and covers negative pressures to -850 mbar up to its full-scale positive range.
What environmental limits should users observe during operation?
Operate between -10 °C and 55 °C with specified relative-humidity limits and up to 3000m altitude
storage extends beyond these values.
Supplied with
protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)
相關連結
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator
- Fluke 717 -850 mbar to 7 bar Pressure Calibrator
- Fluke 717 -850 mbar to 2 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20 bar Pressure Calibrator