Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- RS庫存編號:
- 351-2809
- 製造零件編號:
- FLUKE-718 30
- 製造商:
- Fluke
小計(1 件)*
TWD166,818.00
(不含稅)
TWD175,158.90
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD166,818.00 |
* 參考價格
- RS庫存編號:
- 351-2809
- 製造零件編號:
- FLUKE-718 30
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Maximum Pressure Measurement | 2bar | |
| Battery Type | Alkaline | |
| Product Type | Pressure Calibrator | |
| Accuracy | ±0.015 % | |
| Minimum Pressure Measurement | -850mbar | |
| Resolution | 0.1 mbar | |
| Data Logging | No | |
| Model Number | 718 | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | No | |
| Width | 94mm | |
| Height | 66mm | |
| Length | 216mm | |
| Hazardous Area Certification | NO | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Maximum Pressure Measurement 2bar | ||
Battery Type Alkaline | ||
Product Type Pressure Calibrator | ||
Accuracy ±0.015 % | ||
Minimum Pressure Measurement -850mbar | ||
Resolution 0.1 mbar | ||
Data Logging No | ||
Model Number 718 | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals No | ||
Width 94mm | ||
Height 66mm | ||
Length 216mm | ||
Hazardous Area Certification NO | ||
豁免
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, 2 Bar Maximum Pressure Measurement, ±0.015 % Accuracy - FLUKE-718 30
This handheld pressure calibrator is a compact, battery-powered instrument designed to generate and measure pressure while simultaneously reading current for field calibration of transmitters, gauges and switches. It operates across a negative to positive pressure span and is intended for on-site diagnostic and maintenance tasks in automation, electronics, electrical and mechanical environments.
Features & Benefits
• ±0.015% mA accuracy for precise loop measurement and validation
• 0.1 mbar resolution pressure calibrator for fine pressure discrimination
• Battery powered pressure calibrator 20 h typical runtime for extended field work
• Portable pressure calibrator ±0.015% accuracy with integrated pump for single‑tech use
• Pressure calibrator −850 mbar to 2 bar native range for low-to-mid pressure systems
• LCD pressure calibrator Alkaline battery operation for simple battery replacement
• 0.1 mbar resolution pressure calibrator for fine pressure discrimination
• Battery powered pressure calibrator 20 h typical runtime for extended field work
• Portable pressure calibrator ±0.015% accuracy with integrated pump for single‑tech use
• Pressure calibrator −850 mbar to 2 bar native range for low-to-mid pressure systems
• LCD pressure calibrator Alkaline battery operation for simple battery replacement
**Applications**
• Suitable for commissioning and checking pressure transmitters in process plants
• Ideal for testing pressure switches and performing switch trip verification
• Used with control‑loop maintenance to measure and source 4–20 mA signals
• Can be used for on‑site gauge calibration where portability is required
• Ideal for testing pressure switches and performing switch trip verification
• Used with control‑loop maintenance to measure and source 4–20 mA signals
• Can be used for on‑site gauge calibration where portability is required
What power source does it use and how many batteries are required?
It uses standard 9V alkaline cells and requires two batteries in the unit for normal operation.
How does the tool cope if process fluid reaches the pump?
The pump includes protected check valves and a removable valve assembly that can be cleaned in the field to remove residue.
What measurement functions are available to capture transient behaviour?
It provides zero, minimum, maximum and hold functions Plus damping to Record changing values during tests.
What loop drive capability does it provide for powering transmitters?
It can supply loop power up to 24V dc and drive 20 mA into 1000 Ω with adequate battery voltage.
How is pressure displayed and what simultaneous data is visible?
The LCD shows a five‑digit pressure reading alongside the measured current for concurrent pressure and mA observation.
Supplied with
protective yellow holster, test lead set, crocodile clips, 9V alkaline battery (fitted)
相關連結
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 6.895 bar Pressure Calibrator
- Fluke 718 -68.9 mbar to 68.9 mbar Pressure Calibrator
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 717 -850 mbar to 2 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20.68 bar Pressure Calibrator
- Fluke 717 -850 mbar to 6.895 bar Pressure Calibrator
- Fluke 719 -850 mbar to 8 bar Pressure Calibrator