Block 6 V ac 1 Output Through Hole PCB Transformer, EN 61558-2-6 2009, CSA 22.2, UL 5085-1/-2 0.35 VA
- RS庫存編號:
- 732-0525
- Distrelec 貨號:
- 156-00-620
- 製造零件編號:
- VB 0,35/1/6
- 製造商:
- Block
暫時無法供應
我們無法確定此產品何時有貨,RS 預計將其從我們的產品目錄中移除。
替代產品
該產品我們目前不提供。 這是我們推薦的替代產品。
Each
TWD284.00
(不含稅)
TWD298.20
(含稅)
- RS庫存編號:
- 732-0525
- Distrelec 貨號:
- 156-00-620
- 製造零件編號:
- VB 0,35/1/6
- 製造商:
- Block
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Block | |
| Product Type | PCB Transformer | |
| Secondary Voltage | 6 V ac | |
| Primary Voltage | 230 V ac | |
| Number of Outputs | 1 | |
| Length | 24mm | |
| Width | 22.7 mm | |
| Depth | 15mm | |
| Power | 0.35VA | |
| Weight | 20g | |
| Mount Type | Through Hole | |
| Minimum Operating Temperature | -20°C | |
| Winding Type | Single Secondary, Single Primary | |
| PCB Transformer Current | 0.058A | |
| Efficiency | 30% | |
| Maximum Operating Temperature | 70°C | |
| Minimum Operating Frequency | 50Hz | |
| Series | VB | |
| Standards/Approvals | EN 61558-2-6 2009, CSA 22.2, UL 5085-1/-2 | |
| Maximum Operating Frequency | 60Hz | |
| 選取全部 | ||
|---|---|---|
品牌 Block | ||
Product Type PCB Transformer | ||
Secondary Voltage 6 V ac | ||
Primary Voltage 230 V ac | ||
Number of Outputs 1 | ||
Length 24mm | ||
Width 22.7 mm | ||
Depth 15mm | ||
Power 0.35VA | ||
Weight 20g | ||
Mount Type Through Hole | ||
Minimum Operating Temperature -20°C | ||
Winding Type Single Secondary, Single Primary | ||
PCB Transformer Current 0.058A | ||
Efficiency 30% | ||
Maximum Operating Temperature 70°C | ||
Minimum Operating Frequency 50Hz | ||
Series VB | ||
Standards/Approvals EN 61558-2-6 2009, CSA 22.2, UL 5085-1/-2 | ||
Maximum Operating Frequency 60Hz | ||
- COO (Country of Origin):
- DE

Transformers PCB Mount, Short Circuit Proof, VB & PT Series
230Va.c. 50 to 60Hz primary
Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval)
VB series (0.35 - 3.2VA) are inherently short circuit proof
PT series (4.5 - 22VA) are protected by internal PTC device
Compact design
Vacuum epoxy resin moulded to UL94-V0 rating
Double section glass fibre reinforced polyamide bobbins
100% electrical and flash tested
High efficiency and low temperature rise
Low inter-winding capacitance
Low radiated noise
Extra fixing holes for secure boarding mounting on 4.5VA and above
Approvals
ENEC 10; UL recognised component
Standards
EN 61558
相關連結
- Block 6V ac 1 Output Through Hole PCB Transformer CE IEC/EN VDE
- Block 6V ac 2 Output Through Hole PCB Transformer, 0.35VA
- Block 24V ac 1 Output Through Hole PCB Transformer, 0.35VA
- Block 18V ac 1 Output Through Hole PCB Transformer, 0.35VA
- Block 9V ac 1 Output Through Hole PCB Transformer, 0.35VA
- Block 15V ac 1 Output Through Hole PCB Transformer, 0.35VA
- Block 12V 1 Output Through Hole PCB Transformer CE EN61558-2-6 UL
- Block 15V 2 Output Through Hole PCB Transformer CE EN61558-2-6 UL