規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Power Rating | 0.25kW | |
| Product Type | DOL Starter | |
| Sub Type | DOL | |
| Number of Phases | 3 | |
| Current Rating | 1.4A | |
| IP Rating | IP20, IP40 | |
| Number of Poles | 3 | |
| Overall Length | 66mm | |
| Maximum Voltage | 690V ac | |
| Standards/Approvals | CSA C22.2 No. 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 Type E | |
| Hazardous Area Certification | ATEX | |
| Overall Width | 45mm | |
| Series | LUC | |
| Overall Depth | 60mm | |
| Better World Product | Yes | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Power Rating 0.25kW | ||
Product Type DOL Starter | ||
Sub Type DOL | ||
Number of Phases 3 | ||
Current Rating 1.4A | ||
IP Rating IP20, IP40 | ||
Number of Poles 3 | ||
Overall Length 66mm | ||
Maximum Voltage 690V ac | ||
Standards/Approvals CSA C22.2 No. 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 Type E | ||
Hazardous Area Certification ATEX | ||
Overall Width 45mm | ||
Series LUC | ||
Overall Depth 60mm | ||
Better World Product Yes | ||
豁免
- COO (Country of Origin):
- FR
Schneider Electric LUC Series DOL Starter, 1.4A Current, 0.25kW Power Rating - LUCA1XBL
This DOL starter is a Compact three-phase motor starter designed for direct-on-line motor control and protection in industrial installations. It provides thermal-magnetic protection, phase-failure sensitivity and manual reset capability for low-power motors up to 0.25 kW at 400 to 440 V, operating on a 24V DC control supply. The unit is intended for use with compatible plug-in power bases and reversing contactor breakers in automated control systems.
Features & Benefits
• Thermal protection adjustable 0.35 to 1.4A for precise overload control
• Thermal overload class 10 for short delay before trip
• Thermal-magnetic trip threshold 14.2xIr for short-circuit discrimination
• 24V DC control circuit with 20 to 27V operational limits for secure actuation
• ATEX certification enabling use in specified hazardous areas
• IP20 front panel with IP40 external front protection for varied panel zones
• Thermal overload class 10 for short delay before trip
• Thermal-magnetic trip threshold 14.2xIr for short-circuit discrimination
• 24V DC control circuit with 20 to 27V operational limits for secure actuation
• ATEX certification enabling use in specified hazardous areas
• IP20 front panel with IP40 external front protection for varied panel zones
Applications
• Suitable for motor starters in conveyor and pump control panels
• Ideal for small machine tool motor protection up to 0.25 kW
• Used with plug-in power bases LUB12/32/38 and LUB120/320/380 in control racks
• Can be used for reversing with compatible LU2B contactor breakers
• Suitable for installations requiring ATEX-certified control components
• Ideal for small machine tool motor protection up to 0.25 kW
• Used with plug-in power bases LUB12/32/38 and LUB120/320/380 in control racks
• Can be used for reversing with compatible LU2B contactor breakers
• Suitable for installations requiring ATEX-certified control components
What control voltages will reliably operate the unit?
The control Coil is rated for 24V DC with an operational range of 20 to 27V and a dropout threshold near 14.5 V.
How quickly does the starter respond electrically during switching?
Operating times are approximately 70 MS to close and 35 MS to open under specified power base conditions.
What environmental extremes can it tolerate in service?
It operates between -25 to 70 °C, stores between -40 to 85 °C, and is rated for altitudes up to 2000 m.
How does the unit handle electromagnetic disturbances?
It meets immunity and emissions limits including 8 kV ESD, 10 V/m radiated field immunity, and fast transient classes up to 4 kV depending on circuit.
Note
'For use with' refers to a compatible power base in amps.
Warning
Schneider are in the process of amending the colour of the TeSys range, from White to Black. This means that the stock you receive could be either of these colours. Please be assured that the colour change in no way affects the Fit, Form or Function of the product.
相關連結
- Schneider Electric LUC DOL Starter 440V ac 3 Phase, IP40
- Schneider Electric LUC DOL Starter 440V ac 3 Phase, IP40
- Schneider Electric LUC DOL Starter 690V ac 3 Phase, IP40
- Schneider Electric LUC DOL Starter 690V ac 3 Phase, IP40
- Schneider Electric LUC DOL Starter 690V ac 3 Phase, IP40
- Schneider Electric LUC DOL Starter 690V ac 3 Phase, IP40
- Schneider Electric TeSyS LG - LJ DOL Starter 440V ac 3 Phase, IP657
- Schneider Electric TeSys Motor Starter 440V 3 Phase, IP55