Dold Monitoring Relay, 3 Phase, SPDT, DIN Rail, 110V ac, 230 V ac 24 V dc

小計(1 件)*

TWD18,770.00

(不含稅)

TWD19,708.50

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 1 件從 2026年5月04日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD18,770.00

* 參考價格

RS庫存編號:
445-9074
製造零件編號:
BH9097.38/001 3AC400V AC40A
製造商:
Dold
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Dold

Product Type

Monitoring Relay

Electrical Phase

3

Function

Motor Control

Contact Configuration

SPDT

Mount Type

DIN Rail

Switching Voltage

230V ac

Terminal Type

Screw

IP Rating

IP20, IP40

Supply AC Voltage

110, 230V ac

Supply DC Voltage

24 V dc

Minimum Operating Temperature

-20°C

Contact Current

5A

Maximum Operating Temperature

55°C

Series

BH 9097

Length

121mm

Width

45mm

Height

84mm

Standards/Approvals

IEC/EN 61 000-4-2, EN 50 005, IEC/EN 61 000-4-6, IEC/EN 60 529, EN 55 011, DIN 46 228-1/-2/-3/-4, IEC/EN 60 068-2-6, IEC/EN 60255-26, IEC/EN 61 000-4-4, DIN/VDE 0435-303, IEC/EN 60 947-5-1, IEC 60 664-1, UL Subject 94, IEC/EN 61 000-4-5, IEC/EN 61 000-4-3, IEC/EN 60255-1, IEC/EN 60 068-1, IEC/EN 60 715

Load monitor BH 9097


The load monitor is suitable for monitoring electrical industrial drive systems with variable motor loads.

Features:


The BH 9097 load monitor monitors the actual power consumption of electrical loads

The device can be configured via DIP switches for negative load and overload monitoring or for overload monitoring with preliminary warning level

P1 and P2 settings are calibrated as absolute values; configuration via two rotary switches

Test / reset buttons for simple start-up

Switch state indicator via 2 LEDs

For motors up to 22 KW at 3 AC 400 V, without auxiliary voltage

Up to 40 A without external current transformer

Configurable start-up bridging, configurable response delay

Overall width 45 mm

Load monitor


Using the load monitor allows all machines that are driven by electric motors to be monitored securely. This load monitor can be used for early detection of damage to the bearings or gear, blockage or idling of the screw-conveyors or conveyor belts, as well as V-belt failures or filter blockages, in order to prevent more severe damage or machine failures.

The Telehaase load monitor does not require additional sensors or transducers. It can be used without a current transformer from 230 to 6930 W. Even when operating a frequency inverter, monitoring tasks are completed easily. With all load monitors, start-up bridging and a switching delay can be calibrated.

Standards

IEC 255, EN 60255, VDE 0435 part 303

相關連結