Dold Monitoring Relay, SPDT, DIN Rail
- RS庫存編號:
- 240-8995
- 製造零件編號:
- MK9052.11 AC50/60Hz 230V
- 製造商:
- Dold
小計(1 件)*
TWD3,534.00
(不含稅)
TWD3,710.70
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 1 件從 2026年4月27日 起發貨
- 加上 4 件從 2026年5月11日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD3,534.00 |
* 參考價格
- RS庫存編號:
- 240-8995
- 製造零件編號:
- MK9052.11 AC50/60Hz 230V
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Product Type | Monitoring Relay | |
| Contact Configuration | SPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 1.8VA | |
| IP Rating | IP40 | |
| Time Delay | 20 ms | |
| Minimum Operating Temperature | -20°C | |
| Contact Current | 5A | |
| Maximum Operating Temperature | 60°C | |
| Height | 82mm | |
| Standards/Approvals | IEC/EN 60 715, EN 50 005, IEC/EN 60 947-5-1, IEC/EN 60 529, IEC/EN 60 068-1, VDE 0113 § 5.4.2, IEC/EN 60 999-1, IEC/EN 61 000-4-5, EN 55 011, UL Subject 94, DIN 46 228-1/-2/-3/-4, IEC 60 664-1, IEC/EN 60 068-2-6, IEC/EN 60 255, DIN VDE 0435-303, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2 | |
| Length | 99mm | |
| Width | 22.5mm | |
| Series | MK 9052 | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Product Type Monitoring Relay | ||
Contact Configuration SPDT | ||
Mount Type DIN Rail | ||
Power Consumption 1.8VA | ||
IP Rating IP40 | ||
Time Delay 20 ms | ||
Minimum Operating Temperature -20°C | ||
Contact Current 5A | ||
Maximum Operating Temperature 60°C | ||
Height 82mm | ||
Standards/Approvals IEC/EN 60 715, EN 50 005, IEC/EN 60 947-5-1, IEC/EN 60 529, IEC/EN 60 068-1, VDE 0113 § 5.4.2, IEC/EN 60 999-1, IEC/EN 61 000-4-5, EN 55 011, UL Subject 94, DIN 46 228-1/-2/-3/-4, IEC 60 664-1, IEC/EN 60 068-2-6, IEC/EN 60 255, DIN VDE 0435-303, IEC/EN 61 000-4-4, IEC/EN 61 000-4-2 | ||
Length 99mm | ||
Width 22.5mm | ||
Series MK 9052 | ||
- COO (Country of Origin):
- DE

MK9052 - Thermistor motor protection relay
1 input for thermistors or bi-metallic contacts
Wire breakage detection in the sensor circuit
LED for switching status
Rest current principle
1 changeover
22.5 mm overall width
The MK9052 motor protection relay is used to prevent thermal overloads in motors (for example as caused by high switching frequencies, heavy start-up loads, single phase operation, interrupted cooling, high ambient temperature).
Special thermistors (PTC resistors) developed specifically for motor protection are used as temperature sensors. Up to 6 sensors can be switched in sequence; when a fixed resistance level is reached, they cause the output relay of the MK9052 to de-energise.
相關連結
- Dold Monitoring Relay DIN Rail, 230V ac
- Dold Monitoring Relay DIN Rail
- Dold Monitoring Relay DIN Rail 230V ac
- Dold Monitoring Relay DIN Rail, 24 V dc
- Dold Monitoring Relay DIN Rail 230 V ac
- Dold Monitoring Relay 3 Phase DIN Rail 230V ac
- Dold Monitoring Relay DPDT, DIN Rail
- Dold Monitoring Relay SPDT 400V ac