Dold Monitoring Relay, 1, 3 Phase, DPDT, DIN Rail, 24 V dc, 230V ac
- RS庫存編號:
- 240-8844
- 製造零件編號:
- BD5936.17 AC50/60Hz 230V
- 製造商:
- Dold
小計(1 件)*
TWD13,302.00
(不含稅)
TWD13,967.10
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 + | TWD13,302.00 |
* 參考價格
- RS庫存編號:
- 240-8844
- 製造零件編號:
- BD5936.17 AC50/60Hz 230V
- 製造商:
- Dold
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Dold | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 1, 3 | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 3VA | |
| Terminal Type | Plus-Minus Terminal Screws | |
| IP Rating | IP40, IP20 | |
| Supply AC Voltage | 230V ac | |
| Supply DC Voltage | 24 V dc | |
| Minimum Operating Temperature | -15°C | |
| Maximum Operating Temperature | 55°C | |
| Length | 121mm | |
| Series | BD 5936 | |
| Width | 45mm | |
| Height | 74mm | |
| Standards/Approvals | IEC/EN 60255-1, IEC/EN 60255-26, CE, CCC | |
| 選取全部 | ||
|---|---|---|
品牌 Dold | ||
Product Type Monitoring Relay | ||
Electrical Phase 1, 3 | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Power Consumption 3VA | ||
Terminal Type Plus-Minus Terminal Screws | ||
IP Rating IP40, IP20 | ||
Supply AC Voltage 230V ac | ||
Supply DC Voltage 24 V dc | ||
Minimum Operating Temperature -15°C | ||
Maximum Operating Temperature 55°C | ||
Length 121mm | ||
Series BD 5936 | ||
Width 45mm | ||
Height 74mm | ||
Standards/Approvals IEC/EN 60255-1, IEC/EN 60255-26, CE, CCC | ||
- COO (Country of Origin):
- DE


BD5936.17 - Standstill monitor
Wire breakage detection in the measurement circuit
Positively driven output contacts: 2 NO, 2 NC for 250 Vac
LED displays for motor standstill, wire breakage and operating voltage
Overall width 45 mm
Standstill recognition for 3-phase and single-phase asynchronous motors, e.g. for safety door lock releases on machine tools or for activating parking brakes.
The BD5936.17 measures the induced voltage of the slowing motor at two terminals on the stator winding. No initiator etc. is necessary. Frequency converter-driven motors cannot be monitored with these devices due to the leakage currents from their power semiconductors.
Rotation Sensing
All units have standard panel cut out of 45 x 45mm and SPCO output
相關連結
- Dold Monitoring Relay DPDT, DIN Rail
- Dold Monitoring Relay DIN Rail, 24 V dc
- Dold Monitoring Relay DIN Rail 230 V ac
- Dold Monitoring Relay DIN Rail
- Dold Monitoring Relay DIN Rail
- Dold Monitoring Relay DPDT 230V ac, 400 V ac
- Dold Monitoring Relay DIN Rail 230V ac
- Dold Monitoring Relay DPDT 0.1A to 10A, 230V ac