ABB, Tmax XT, Tmax XT Molded Case Circuit Breaker 3-Pole 52A, Breaking Capacity 65 kA, Fixed

小計(1 件)*

TWD10,404.00

(不含稅)

TWD10,924.20

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 1 件從 2026年7月27日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,404.00

* 參考價格

RS庫存編號:
237-6225
製造零件編號:
1SDA067051R1 XT2N 160 MA 52 FF
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

Tmax XT

Number of Poles

3

Current Rating

52A

Breaking Capacity

65kA

Rated AC Voltage

690V ac

Mount Type

Fixed

Rated DC Voltage

500V dc

Terminal Type

Fixed

Standards/Approvals

IEC, RoHS, CE

Width

90mm

Depth

82.5mm

Height

130mm

Tripping Mechanism

Magnetic

Reset Actuator Type

Lever

COO (Country of Origin):
IT

ABB Tmax XT Series Molded Case Circuit Breaker, 52A Current Rating, 65kA Breaking Capacity - 1SDA067051R1 XT2N 160 MA 52 FF


This moulded case circuit breaker provides overcurrent protection for three-phase industrial installations, functioning as a fixed-terminal protective device with a manual reset lever. It is intended for use in electrical distribution and motor protection where Compact fixed mounting and magnetic tripping are required.

Features and Benefits:


• 65kA breaking capacity delivers high fault interruption performance • 52A rating enables defined protection for medium-current circuits • Magnetic trip operation offers Rapid short-circuit response • Fixed Terminal arrangement simplifies secure panel installation • Rated for 690V AC and 500V DC supports mixed-supply environments • Conforms to IEC, RoHS and CE standards for regulatory alignment

Applications


• Suitable for protecting industrial motor circuits requiring fast fault isolation • Ideal for distribution panels in manufacturing and automation centres • Used with DC and AC supplies in mixed-voltage installations • Can be used for switchgear retrofits needing a Compact fixed MCCB

How is the device reset after a trip?


A manual lever actuator is provided to return the breaker to service following a trip event.

What pole configuration does the unit use?


It uses a three-pole arrangement to interrupt all phases simultaneously for balanced system protection.

What mounting approach is required for installation?


The breaker is designed for fixed mounting and requires secure attachment to a panel or enclosure.

Which Terminal type is fitted and how does that affect connections?


Fixed terminals are used, requiring appropriate cable lugs and secure bolted connections during wiring.