ABB, Tmax XT, Tmax XT Molded Case Circuit Breaker 3-Pole 5A, Breaking Capacity 65 kA, Fixed

小計(1 件)*

TWD11,098.00

(不含稅)

TWD11,652.90

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 庫存資訊目前無法存取 - 請稍後再回來查看
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD11,098.00

* 參考價格

RS庫存編號:
237-6207
製造零件編號:
1SDA067005R1 XT2N 160 TMD 5A FF
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Molded Case Circuit Breaker

Range

Tmax XT

Series

Tmax XT

Number of Poles

3

Current Rating

5A

Breaking Capacity

65kA

Rated AC Voltage

690V ac

Mount Type

Fixed

Rated DC Voltage

500V dc

Terminal Type

Fixed

Standards/Approvals

RoHS, CE, IEC

Width

90mm

Depth

82.5mm

Height

130mm

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Lever

COO (Country of Origin):
IT

ABB Tmax XT Series Molded Case Circuit Breaker, 5A Current Rating, 65kA Breaking Capacity - 1SDA067005R1 XT2N 160 TMD 5A FF


This moulded case circuit breaker provides overcurrent protection for three-phase installations, combining thermal and magnetic tripping to safeguard conductors and equipment in industrial electrical systems. It is designed for fixed mounting and operates within medium-voltage environments where both AC and DC interruption capabilities are required.

Features and Benefits:


• Rated for 690V AC operation protecting high-voltage three-phase systems
• 500V DC rating enabling use in DC supply and control circuits
• 65kA breaking capacity minimising damage during fault clearance
• Thermal magnetic trip delivering combined overload and short-circuit protection
• Fixed Terminal and mount facilitating secure, vibration-resistant installation
• Reset lever offering Rapid manual reclosure after fault resolution

Applications


• Suitable for motor control panel protection in manufacturing plants
• Ideal for distribution boards in automation facilities
• Used for protecting DC feed circuits in battery-backed systems
• Can be used for branch-circuit protection in electrical switchrooms

How many poles does it provide for three-phase systems?


It is a three-pole device that isolates and protects all three phases simultaneously.

What Terminal and mounting arrangement should installers expect?


Installers will find fixed terminals and a fixed mount configuration for stable, permanent installation.

How does the trip mechanism respond to different fault types?


The thermal element responds to prolonged overloads while the magnetic element actuates on high-magnitude short-circuit currents.

Which approvals indicate its conformity to recognised standards?


It meets RoHS, CE and IEC requirements for electrical safety and materials compliance.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。