Eaton xEffect MCB, 1P, 4A Curve C, 240 → 415V AC, 48V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 922-6894
- 製造零件編號:
- 102082 FAZ-C4/1-NA
- 製造商:
- Eaton
小計(1 件)*
TWD1,279.00
(不含稅)
TWD1,342.95
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 32 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD1,279.00 |
* 參考價格
- RS庫存編號:
- 922-6894
- 製造零件編號:
- 102082 FAZ-C4/1-NA
- 製造商:
- Eaton
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 4A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240 → 415V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Circuit Breaker Type | MCB | |
| Length | 17.8mm | |
| Width | 66mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Break Time | Instantaneous | |
| Terminal Contact Type | Screw | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal-Magnetic | |
| 選取全部 | ||
|---|---|---|
品牌 Eaton | ||
Number of Poles 1 | ||
Current Rating 4A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240 → 415V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Circuit Breaker Type MCB | ||
Length 17.8mm | ||
Width 66mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
Break Time Instantaneous | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal-Magnetic | ||
Eaton MCB, 4A Current Rating, Type C Tripping Characteristics - 102082 FAZ-C4/1-NA
This MCB is a compact thermal-magnetic circuit breaker designed for reliable electrical protection. It features a single pole configuration with a current rating of 4A, ideal for a diverse range of applications. Measuring 17.7mm in width and 105mm in length, it is suitable for DIN rail mounting, making it a versatile choice for various installations.
Features & Benefits
• Instantaneous break time ensures quick fault response
• Type C characteristics provide protection against overloads
• Designed for 230V to 400V AC applications for flexibility
• 10 kA breaking capacity handles high fault levels
• Screw terminal design allows for easy and secure connections
• Compact size optimises space within electrical panels
• Type C characteristics provide protection against overloads
• Designed for 230V to 400V AC applications for flexibility
• 10 kA breaking capacity handles high fault levels
• Screw terminal design allows for easy and secure connections
• Compact size optimises space within electrical panels
Applications
• Ideal for commercial and industrial distribution boards
• Used in automation and control systems for added safety
• Suitable for involving motors and transformers
• Commonly deployed in residential electrical systems for protection
• Used in automation and control systems for added safety
• Suitable for involving motors and transformers
• Commonly deployed in residential electrical systems for protection
What tripping characteristics should I consider when using this device?
The Type C tripping characteristics are ideal for applications with high inrush currents, such as motors, ensuring that they trip under overload conditions while remaining stable during normal operation.
How does this circuit breaker respond to faults in an electrical circuit?
It utilises a thermal-magnetic tripping mechanism to provide both overload and short-circuit protection, ensuring the circuit is interrupted immediately in the event of a fault, thus enhancing electrical safety.
What is the significance of the breaking capacity for this circuit breaker?
The 10 kA breaking capacity indicates its ability to safely interrupt a fault current of up to 10,000 amps, making it suitable for high-demand environments where fault levels may be significant.
Note
Eaton formerly known as Moeller
相關連結
- Eaton xEffect MCB 4A Curve D 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 13A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 20A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 1A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 2A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 500mA Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 10A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 6A Curve C 48V DC, 10 kA Breaking Capacity