Schneider Electric Acti9 IC60N Miniature Circuit Breaker, 4-Pole, 16 A, Type C, 12 V DC, 10 kA Breaking Capacity
- RS庫存編號:
- 734-9163
- 製造零件編號:
- A9F77416
- 製造商:
- Schneider Electric
此圖片僅供參考,請參閲產品詳細資訊及規格
可享批量折扣
小計(1 件)*
TWD7,560.00
(不含稅)
TWD7,938.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 16 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 - 4 | TWD7,560.00 |
| 5 - 9 | TWD6,417.00 |
| 10 + | TWD6,274.00 |
* 參考價格
- RS庫存編號:
- 734-9163
- 製造零件編號:
- A9F77416
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Number of Poles | 4 | |
| Product Type | Miniature Circuit Breaker | |
| Current Rating | 16 A | |
| Tripping Characteristics | Type C | |
| Rated DC Voltage | 12 V | |
| Mount Type | DIN Rail | |
| Breaking Capacity | 10kA | |
| Range | Acti9 | |
| Series | IC60N | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Depth | 78.5mm | |
| Height | 85mm | |
| Standards/Approvals | REACH, EN/IEC 60947-2, EN/IEC 60898-1, RoHS | |
| Width | 72 mm | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| Break Time | Instantaneous | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Number of Poles 4 | ||
Product Type Miniature Circuit Breaker | ||
Current Rating 16 A | ||
Tripping Characteristics Type C | ||
Rated DC Voltage 12 V | ||
Mount Type DIN Rail | ||
Breaking Capacity 10kA | ||
Range Acti9 | ||
Series IC60N | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Depth 78.5mm | ||
Height 85mm | ||
Standards/Approvals REACH, EN/IEC 60947-2, EN/IEC 60898-1, RoHS | ||
Width 72 mm | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
Break Time Instantaneous | ||
- COO (Country of Origin):
- FR
Schneider Electric Acti9 i60N MCBs 4 Pole
Acti 9 iC60N series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.
VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Benefits and Features
Standards
Q: What is the differences in the Tripping Curves B, C, and D?
相關連結
- Schneider Electric Acti 9 iC60N MCB 25A Curve C 12 → 250V DC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 40A Curve C 12 → 250V DC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 16A Curve C 12 → 250V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 16A Curve D 12 → 144V DC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 16A Curve C 12 → 144V DC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 100 → 130V AC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 100 → 130V AC, 6 kA Breaking Capacity
- Schneider Electric Acti 9 iC60N MCB 6A Curve C 250V DC, 6 kA Breaking Capacity