Schneider Electric Acti9 Acti9 iC60 Miniature Circuit Breaker, 2-Pole, 2 A, Type C, 100 V, 12 V, 130 V, 220 V, 240 V,
- RS庫存編號:
- 734-9131
- 製造零件編號:
- A9F74202
- 製造商:
- Schneider Electric
小計(1 件)*
TWD4,130.00
(不含稅)
TWD4,336.50
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 71 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,130.00 |
* 參考價格
- RS庫存編號:
- 734-9131
- 製造零件編號:
- A9F74202
- 製造商:
- Schneider Electric
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Schneider Electric | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 2 | |
| Current Rating | 2 A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 100 V, 12 V, 130 V, 220 V, 240 V, 380 V, 400 V, 415 V, 60 V | |
| Rated DC Voltage | 144 V dc | |
| Mount Type | DIN Rail | |
| Breaking Capacity | 6kA | |
| Range | Acti9 | |
| Series | Acti9 iC60 | |
| Terminal Type | Screw | |
| IP Rating | IP20 | |
| Standards/Approvals | EN/IEC 60898-1, EN/IEC 60947-2, REACH, RoHS | |
| Height | 85mm | |
| Width | 36 mm | |
| Depth | 78.5mm | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| Break Time | Instantaneous | |
| 選取全部 | ||
|---|---|---|
品牌 Schneider Electric | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 2 | ||
Current Rating 2 A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 100 V, 12 V, 130 V, 220 V, 240 V, 380 V, 400 V, 415 V, 60 V | ||
Rated DC Voltage 144 V dc | ||
Mount Type DIN Rail | ||
Breaking Capacity 6kA | ||
Range Acti9 | ||
Series Acti9 iC60 | ||
Terminal Type Screw | ||
IP Rating IP20 | ||
Standards/Approvals EN/IEC 60898-1, EN/IEC 60947-2, REACH, RoHS | ||
Height 85mm | ||
Width 36 mm | ||
Depth 78.5mm | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
Break Time Instantaneous | ||
- COO (Country of Origin):
- FR
Schneider Electric MCB, 2 Poles, 6kA Breaking Capacity - Acti 9 Series - A9F74202
Features & Benefits
• Operating temperature range of -35°C to +70°C makes it suitable for use in harsh environments
• Mean time between failures of 20,000 cycles (mechanical) and 10,000 cycles (electrical) for a long service life
Applications
• Industrial facilities
• Commercial premises
• Contaminated environments
What's the difference between a single-pole and a double-pole circuit breaker?
A single-pole circuit breaker, usually used with 120V circuits, consists of one hot wire and one neutral wire. A double-pole circuit breaker, usually used with a 240V circuit, has two hot wires connected by a neutral wire.
Standards
EN/IEC 60947-2, EN/IEC 60898-1.
相關連結
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 20 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 2 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 25 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 16 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 10 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 4 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 16 A 100 V 130 V 240 V
- Schneider Electric Acti9 IC60N Miniature Circuit Breaker 63 A 100 V 130 V 240 V