ABB SMISSLINE TP S400M Miniature Circuit Breaker, 4-Pole, 16A, Type K, 415V ac AC, 52.20 kA Breaking Capacity

小計(1 件)*

TWD8,988.00

(不含稅)

TWD9,437.40

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 從 2026年12月14日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD8,988.00

* 參考價格

RS庫存編號:
246-2686
製造零件編號:
2CCS573103R8467
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

4

Current Rating

16A

Tripping Characteristics

Type K

Rated AC Voltage

415V ac

Breaking Capacity

52.20kA

Range

SMISSLINE TP

Series

S400M

Terminal Type

Screw

IP Rating

IP20

Standards/Approvals

IEC/EN 60947-2

Width

72mm

Depth

75mm

Height

91mm

Tripping Mechanism

Electromechanic, Thermal

Reset Actuator Type

I/O Actuator

COO (Country of Origin):
CH

ABB S400M Series Miniature Circuit Breaker, 16A Current, 415V Rated AC Voltage - 2CCS573103R8467


This miniature circuit breaker provides overcurrent protection for low-voltage installations and is intended for four-pole distribution circuits. It operates within three-phase systems at rated AC voltages up to 415V and uses a combined thermal and electromechanical trip arrangement to interrupt fault currents. The device is suited to panel mounting where standardised protection and a Compact footprint are required.

Features and Benefits:


• 52.20kA breaking capacity protects against high fault currents
• Type K tripping characteristic handles motor-start and inductive loads
• 4-pole configuration enables simultaneous multi-phase disconnection
• 16A current rating supports moderate load circuits
• I/O reset actuator permits clear manual on/off operation

Applications


• Suitable for three-phase distribution panels in commercial buildings
• Ideal for circuits with frequent motor starts and inductive loads
• Used with switchboards requiring coordinated multi-pole protection
• Can be used for feeder protection where high interrupting capacity is needed

What earth and enclosure protection level does it provide?


The enclosure meets IP20 protection, which guards against access to hazardous parts and solid objects larger than 12 mm.

How are the conductors terminated?


Conductors connect via screw terminals designed for secure clamping under vibration.

What standards guide its short-circuit performance?


Short-circuit interruption and design align with IEC/EN 60947-2 requirements.

Which mechanism initiates trip under overload and short-circuit?


Thermal action responds to prolonged overload while the electromechanical release trips on Rapid fault currents.