ABB SN201 MCB, 1+N, 32A Curve C, 230V AC, 4.5 kA Breaking Capacity
- RS庫存編號:
- 186-3474
- 製造零件編號:
- 2CSS245102R0324
- 製造商:
- ABB
小計(1 件)*
TWD446.00
(不含稅)
TWD468.30
(含稅)
訂單超過 $1,300.00 免費送貨
有限的庫存
- 22 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD446.00 |
* 參考價格
- RS庫存編號:
- 186-3474
- 製造零件編號:
- 2CSS245102R0324
- 製造商:
- ABB
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | ABB | |
| Number of Poles | 1+N | |
| Current Rating | 32A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 230V | |
| Breaking Capacity at Maximum Voltage Rating | 4.5 kA | |
| Series | SN201 | |
| Circuit Breaker Type | MCB | |
| Width | 18mm | |
| Length | 69mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 85mm | |
| Model Number | SN201 L C32-L | |
| 選取全部 | ||
|---|---|---|
品牌 ABB | ||
Number of Poles 1+N | ||
Current Rating 32A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 230V | ||
Breaking Capacity at Maximum Voltage Rating 4.5 kA | ||
Series SN201 | ||
Circuit Breaker Type MCB | ||
Width 18mm | ||
Length 69mm | ||
Mounting Style DIN Rail Mount | ||
Depth 85mm | ||
Model Number SN201 L C32-L | ||
- COO (Country of Origin):
- IT
ABB SN201 Series MCB, 69mm Length, 1P+N - 2CSS245102R0324
This MCB is designed for efficient circuit protection and reliable operation across various applications. It plays a key role in preventing electrical overloads and faults, contributing to the safety and stability of electrical systems while ensuring uninterrupted service.
Features & Benefits
• Combines 1P+N functionality for versatile circuit protection
• Rated for 32A current, increasing operational capacity
• Can handle breaking capacity up to 4.5 kA at 230V
• Compact width of 18mm optimises space in electrical panels
• Rated for 32A current, increasing operational capacity
• Can handle breaking capacity up to 4.5 kA at 230V
• Compact width of 18mm optimises space in electrical panels
Applications
• Used in commercial building electrical distribution systems
• Suitable for residential installations requiring circuit protection
• Suitable for residential installations requiring circuit protection
What steps are necessary for installation?
Ensure the power is completely shut off. Mount the MCB on a DIN rail, securely fixed. Connect the incoming and outgoing terminals according to the specific load requirements, adhering to local electrical codes.
How does the tripping mechanism function?
The Type C tripping characteristics protect against current surges, making it suited for inductive loads like motors and transformers. This ensures that normal operation does not cause nuisance tripping.
What is the optimal environment for operation?
The device is intended for standard indoor environments. It should be installed away from direct moisture, extreme temperatures, and dust accumulation to maintain optimal performance and longevity.
相關連結
- ABB SN201 MCB 2A Curve C 4.5 kA Breaking Capacity
- ABB SN201 MCB 16A Curve C 4.5 kA Breaking Capacity
- ABB SN201 MCB 20A Curve C 4.5 kA Breaking Capacity
- ABB SN201 MCB 32A Curve C
- ABB SN201 MCB 16A Curve C 10 kA Breaking Capacity
- ABB SN201 MCB 6A Curve C 6 kA Breaking Capacity
- ABB SN201 MCB 6A Curve D 10 kA Breaking Capacity
- ABB SN201 MCB 10A Curve C 6 kA Breaking Capacity