ABB S-ARC1 S-ARC1 Miniature Circuit Breaker, 1-Pole, 16 A, Type B, 240 V ac AC, 6 kA Breaking Capacity

小計(1 件)*

TWD7,692.00

(不含稅)

TWD8,076.60

(含稅)

Add to Basket
選擇或輸入數量
庫存資訊目前無法存取 - 請稍後再回來查看
單位
每單位
1 +TWD7,692.00

* 參考價格

RS庫存編號:
175-9929
製造零件編號:
2CSA255901R9165 S-ARC1 B16
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

1

Tripping Characteristics

Type B

Breaking Capacity

6kA

Mount Type

DIN Rail

Range

S-ARC1

Series

S-ARC1

Terminal Type

Cage Terminal

IP Rating

IP20, IP40

Standards/Approvals

IEC/EN 60898-1, IEC/EN 62606

Height

85mm

Depth

69mm

Tripping Mechanism

Thermal Magnetic

Reset Actuator Type

Toggle Switch

COO (Country of Origin):
IT

ABB S-ARC1 Series MCB, 16A Current Rating , 1+N Poles - 2CSA255901R9165 S-ARC1 B16


This MCB, a pivotal device in electrical distribution systems, offers reliable protection against short circuits. It is designed by ABB, it operates at a rated voltage of 240V and features dimensions of 35mm in width and 69mm in depth and length. This device is a 1+N circuit breaker, encompassing a Type B tripping characteristic, making it suitable for various applications while ensuring safety and performance.

Features & Benefits


• Provides short circuit protection to enhance safety
• Rated for 16 A current to suit diverse applications
• Type B MCB ensures reliable tripping for standard loads
• Compact DIN rail mount design facilitates easy installation
• 6 kA breaking capacity protects against overcurrents
• Toggle switch actuator for straightforward reset functionality

Applications


• Used in residential electrical installations for circuit protection
• Integrated into industrial automation systems for overload management
• Employed in commercial settings to safeguard electrical circuits
• Utilised in consumer electronics for enhanced safety protocols

What is the significance of the tripping characteristics in this device?


The Type B tripping characteristics ensure that the MCB effectively trips under standard load conditions, protecting circuits from overloads while allowing temporary surges.

Can this circuit breaker handle high inrush currents?


Yes, the Type B characteristic is designed to tolerate high inrush currents, making it suitable for applications with motors or inductive loads where temporary surges may occur.

How does the design of this device facilitate installation?


The DIN rail mount design allows for quick and secure installation within electrical distribution boards, streamlining the process for electricians.

What kind of maintenance is required for this MCB?


Typically, minimal maintenance is required

however, periodic inspections are recommended to ensure it operates correctly and to check for any signs of wear or damage.

相關連結