RS Better World

Siemens SENTRON 5SY4 Miniature Circuit Breaker, 3-Pole, 50A, Type C, 400V ac AC, 60 V dc DC, 10 kA Breaking Capacity

小計(1 件)*

TWD3,839.00

(不含稅)

TWD4,030.95

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 11 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD3,839.00

* 參考價格

我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。

瞭解有關RS Better World產品的更多資訊

RS庫存編號:
124-3180
Distrelec 貨號:
301-37-639
製造零件編號:
5SY4350-7
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Number of Poles

3

Product Type

Miniature Circuit Breaker

Current Rating

50A

Tripping Characteristics

Type C

Rated AC Voltage

400V ac

Rated DC Voltage

60V dc

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

SENTRON

Series

5SY4

Terminal Type

Combined Terminal

IP Rating

IP20

Standards/Approvals

IEC/EN 60947-2/UL1077, IEC/EN 60898-1

Width

54mm

Height

90mm

Depth

76mm

Better World Product

Yes

Better World Claim

Extended Product Life

Reset Actuator Type

Toggle Switch

COO (Country of Origin):
DE

Siemens 5SY4 Series Miniature Circuit Breaker, 50A Current, 400V ac Rated Voltage - 5SY4350-7


This miniature circuit breaker provides overcurrent protection for industrial and infrastructure installations. Designed for three-pole switching with a Type C tripping characteristic, it operates on AC systems up to 400V and on DC supplies up to 60V. The device is suitable for DIN-rail mounting and includes a toggle reset actuator to permit manual reclosure after a trip.

Features and Benefits:


• 50A rated current ensures sustained operational load handling
• 10kA breaking capacity limits fault energy in AC systems
• Type C tripping characteristic protects against moderate inrush currents
• Combined terminals enable flexible conductor connection options
• IP20 protection offers touch-safe operation in enclosed panels

Applications


• Suitable for industrial switchboards requiring three-pole protection
• Ideal for infrastructure distribution circuits with moderate fault levels
• Used with AC supplies at 50/60Hz for general motor protection
• Can be used in DC up to 60V for control circuits
• Suitable for DIN-rail panel assemblies in confined enclosures

What conductor sizes can be connected to the terminals?


Solid, stranded and finely stranded conductors from 0.75mm² up to 35mm² can be used, with finely stranded up to 25mm² when using end ferrules.

How does temperature affect continuous current capability?


The operational current decreases with ambient temperature

examples include 48A at 40°C and 43.8A at 60°C for AC operation.

What mechanical endurance can be expected from the device?


The breaker is specified for a typical mechanical service life of 10,000 operating cycles.

Which standards govern its design and testing?


It conforms to IEC/EN 60947-2 and IEC/EN 60898-1 and carries UL1077 recognition for applicable tests.