RS Better World

Siemens SENTRON 5SY4 Miniature Circuit Breaker, 3-Pole, 40A, Type C, 400V ac AC, 60 V dc DC, 10 kA Breaking Capacity

小計(1 件)*

TWD6,460.00

(不含稅)

TWD6,783.00

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 10 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD6,460.00

* 參考價格

我們的 Better World 產品系列可讓您輕鬆選擇值得信賴的環保產品。

瞭解有關RS Better World產品的更多資訊

RS庫存編號:
124-3177
Distrelec 貨號:
300-24-120
製造零件編號:
5SY4340-7
製造商:
Siemens
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Siemens

Product Type

Miniature Circuit Breaker

Number of Poles

3

Current Rating

40A

Tripping Characteristics

Type C

Rated AC Voltage

400V ac

Rated DC Voltage

60V dc

Mount Type

DIN Rail

Breaking Capacity

10kA

Range

SENTRON

Series

5SY4

Terminal Type

Combined Terminal

IP Rating

IP20

Height

90mm

Width

54mm

Standards/Approvals

IEC/EN 60947-2/UL1077, IEC/EN 60898-1

Depth

76mm

Better World Claim

Extended Product Life

Better World Product

Yes

COO (Country of Origin):
DE

Siemens 5SY4 Series Miniature Circuit Breaker, 40A Current, 400V ac Rated Voltage - 5SY4340-7


This miniature circuit breaker is a three-pole protective device designed for DIN-rail distribution systems in industrial and infrastructure environments. It operates on AC supplies up to 400 V and on DC supplies up to 60 V, providing overcurrent and short-circuit interruption with a Type C tripping characteristic. The unit is intended for installation where IP20 touch protection and combined top/bottom terminals are required, and it meets relevant IEC/EN and UL standards for low-voltage switching devices.

Features and Benefits:


• 10 kA breaking capacity delivers defined fault interruption performance
• Type C characteristic protects moderate inrush loads and circuits
• 3-pole construction enables simultaneous multi-phase disconnection
• Combined terminals permit flexible TOP and bottom conductor connection
• DIN-rail mounting allows straightforward panel integration

Applications


• Suitable for three-phase distribution boards in industrial facilities
• Used for motor feeder protection with moderate starting currents
• Ideal for infrastructure electrical panels requiring modular protection
• Can be used for DC control circuits up to 60 V where isolation is needed
• Used with sub-distribution units requiring UL1077 recognition

What is the mechanical lifecycle of the device?


It typically endures 10,000 operating cycles under mechanical operation.

What conductor sizes can be connected to its terminals?


Solid and stranded conductors from 0.75 mm² up to 35 mm² can be fitted, and finely stranded conductors with ferrules up to 25 mm².

How does ambient temperature affect current-carrying capability?


Rated current is 40 A

operational current reduces with temperature, for example to 38.42 A at 40 °C and to 35.04 A at 60 °C.

Which standards and approvals does it comply with?


It conforms to IEC/EN 60898-1 and IEC/EN 60947-2 and holds UL1077 recognition.

What are the tightening torque requirements for the screw terminals?


Terminals require 2.5 N·m to 3.5 N·m torque, equivalent to 22 lbf·in to 31 lbf·in.