ABB S302 MCB, 2P, 32A Curve D, 415V AC, 125V DC, 25 kA Breaking Capacity

小計(1 件)*

TWD8,453.00

(不含稅)

TWD8,875.65

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年2月16日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD8,453.00

* 參考價格

RS庫存編號:
200-755
製造零件編號:
2CDS382001R0321
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

2

Current Rating

32A

Tripping Characteristics

Type D

Rated AC Voltage

415V

Rated DC Voltage

125V

Breaking Capacity at Maximum Voltage Rating

25 kA

Series

S302

Circuit Breaker Type

MCB

Width

35mm

Length

69mm

Mounting Style

DIN Rail

Depth

69mm

Model Number

S302P-D32

Terminal Contact Type

Screw

COO (Country of Origin):
DE

ABB S302 Series MCB, 32A Current Rating, 25kA Breaking Capacity - 2CDS382001R0321


This miniature circuit breaker (MCB) is a reliable electrical circuit protection solution, offering robust operational capabilities. Designed with 2 poles, it has a current rating of 32A, an impressive 25kA breaking capacity, and operates at 415V. The unit conforms to Type D tripping characteristics and is equipped with screw terminals for secure connections. Measuring 35mm in width and 69mm in length, this DIN rail mounted MCB ensures efficient use of space within electrical installations.

Features & Benefits


• Supports a 25kA breaking capacity to protect against faults
• Type D characteristics allow it to handle high inrush currents
• 2-pole design suitable for various applications in automation
• Screw terminal connection ensures robust and secure installation
• Complies with IEC/EN 60947-2 and IEC/EN 60898-1 standards
• Compact dimensions facilitate integration into existing setups

Applications


• Used in commercial electrical installations requiring circuit protection
• Harnessed for industrial to prevent electrical overloads
• Ideal for pairing with automation equipment due to high current tolerance
• Suitable for extensive wiring systems needing reliable components

How does the breaking capacity of this MCB enhance safety?


The 25kA breaking capacity ensures that the device can safely interrupt excessive electrical currents, thereby protecting the entire circuit from damage or fire hazards during faults.

What considerations should be taken into account before installation?


Ensure that the device is mounted on a compatible DIN rail and that all screw terminals are adequately tightened to prevent loose connections that could lead to malfunctions.

Can this MCB handle short-circuit conditions effectively?


Yes, the robust design and Type D tripping characteristics allow it to manage high inrush currents and respond swiftly to short-circuit conditions, providing effective protection.