ABB SU200 M Miniature Circuit Breaker, 1-Pole, 30A, Type K, 277V ac AC, 48 V dc DC, 15 kA Breaking Capacity

小計(1 件)*

TWD4,253.00

(不含稅)

TWD4,465.65

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2027年1月18日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD4,253.00

* 參考價格

RS庫存編號:
200-132
製造零件編號:
2CDS271337R0527
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Miniature Circuit Breaker

Number of Poles

1

Current Rating

30A

Tripping Characteristics

Type K

Rated AC Voltage

277V ac

Rated DC Voltage

48V dc

Mount Type

DIN Rail

Breaking Capacity

15kA

Series

SU200 M

Terminal Type

Double Clamp

IP Rating

IP20, IP40

Standards/Approvals

UL489

Width

17.50mm

Depth

69mm

Height

111mm

Reset Actuator Type

Toggle

COO (Country of Origin):
DE

ABB SU200 M Series Miniature Circuit Breaker, 30A Current, 277V ac Rated Voltage - 2CDS271337R0527


This miniature circuit breaker protects single-pole electrical circuits by interrupting fault currents in low-voltage installations. It is intended for DIN-rail mounting in control panels and distribution boards and provides overcurrent protection where a compact, toggle-reset device is required. The unit conforms to UL489 and is designed for installations requiring both AC and DC rated switching.

Features and Benefits:


• 15kA breaking capacity provides robust fault interruption
• Type K tripping characteristic offers defined selectivity
• Double-clamp terminals enable secure conductor connections
• Toggle-reset actuator allows quick manual reset operation
• IP20

IP40 ingress ratings protect internal components in enclosed environments

Applications


• Used for protection in industrial control systems
• Suitable for single-pole distribution circuits on DIN-rail
• Ideal for mixed AC and DC control
• Can be used in Compact panel assemblies requiring slim devices

What mounting method does it use?


It mounts directly on a standard DIN rail for straightforward installation.

What pole configuration is provided for circuit segregation?


It is supplied as a single-pole device to isolate one conductor.

Which Terminal arrangement supports conductor attachment?


Terminals use a double-clamp design to accept and secure conductors.

How does the reset mechanism operate after a trip?


A manual toggle actuator is used to restore the device to service.

What voltage ratings are applicable for AC and DC applications?


The unit is rated for 277V AC operation and 48V DC operation.