ABB S803N MCB, 3P, 10A Curve C, 690V AC, 36 kA Breaking Capacity

小計(1 件)*

TWD19,347.00

(不含稅)

TWD20,314.35

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年2月16日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD19,347.00

* 參考價格

RS庫存編號:
140-914
製造零件編號:
2CCS893001R0104
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

3

Current Rating

10A

Tripping Characteristics

Type C

Rated AC Voltage

690V

Breaking Capacity at Maximum Voltage Rating

36 kA

Series

S803N

Circuit Breaker Type

MCB

Length

82.5mm

Width

81mm

Mounting Style

DIN Rail

Depth

82.5mm

Model Number

S803N-C10

Terminal Contact Type

Screw

COO (Country of Origin):
AT

ABB S803N Series MCB, 10A Current Rating, 36kA Breaking Capacity - 2CCS893001R0104


This MCB is a high-performance circuit breaker designed for robust electrical systems. With a current rating of 10A and a rated AC voltage of 690V, it features three poles and measures 81mm in width and 82.5mm in depth. The circuit breaker offers exceptional performance with a breaking capacity of 36kA, making it suitable for a variety of applications in residential, commercial, and industrial settings.

Features & Benefits


• Combines thermal and electromechanical tripping for enhanced protection
• Current limiting device protects against overload and short circuits
• Compatible with AC and DC voltages up to 690V
• High breaking capacity ensures safety under maximum fault conditions
• Designed for DIN Rail mounting, facilitating easy installation
• Screw terminal design enhances electrical connectivity and reliability

Applications


• Utilised in residential electrical systems for circuit protection
• Employed in commercial buildings to safeguard electrical installations
• Ideal for industrial environments where high performance is necessary
• Used in automation systems that require robust circuit protection
• Compatible with accessory systems for customised

What kind of maintenance is required for optimal performance?


Regular inspections should be conducted to ensure proper operation and to check for signs of wear or damage. Furthermore, tightening screws as per specified torque values will help maintain electrical connectivity.

How does the breaking capacity affect the overall safety of my installation?


The breaking capacity refers to the MCB's ability to interrupt fault current without causing damage to itself or the electrical circuit. A higher breaking capacity, such as 36kA, significantly improves safety, ensuring that electrical fault conditions are managed effectively.

Can this device accommodate different cable sizes?


Yes, it can connect flexible cables of up to 50mm² and rigid cables of up to 70mm², allowing versatility in installations. Ensure the cable size is appropriate for the specific current rating and application.