ABB S802S MCB, 2P, 10A Curve B, 500V DC, 50 Ka Breaking Capacity

小計(1 件)*

TWD19,025.00

(不含稅)

TWD19,976.25

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年2月02日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD19,025.00

* 參考價格

RS庫存編號:
140-905
製造零件編號:
2CCS862001R1105
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Number of Poles

2

Current Rating

10A

Tripping Characteristics

Type B

Rated DC Voltage

500V

Breaking Capacity at Maximum Voltage Rating

50 Ka

Series

S802S

Circuit Breaker Type

MCB

Width

54mm

Length

82.5mm

Mounting Style

DIN Rail

Depth

82.5mm

Model Number

S802S-UCB10

Terminal Contact Type

Screw

COO (Country of Origin):
AT

ABB S802S Series MCB, 10A Current Rating, 2 Poles - 2CCS862001R1105


This high performance MCB is a 2 pole miniature circuit breaker designed specifically for applications requiring reliable protection. With a current rating of 10A and a breaking capacity of 50kA, it operates at a rated DC voltage of 500V. The compact dimensions measure 54mm in width and 82.5mm in length, making it suitable for DIN rail mounting.

Features & Benefits


• Supports Type B tripping characteristic for standard applications
• Designed for 10A maximum current to ensure effective protection
• Maintains high breaking capacity of 50kA for reliable fault interruption
• Rated for 500V DC operational voltage to suit various systems
• Screw terminal connections simplify secure wiring setups
• Conforms to IEC/EN 60947-2 standards for enhanced safety

Applications


• Used in electrical installations for residential and commercial systems
• Ideal for automation systems requiring circuit protection
• Suitable for use in renewable energy , such as solar power
• Employed in industrial machinery to safeguard against overloads

What are the operational limits regarding temperature for this product?


This circuit breaker operates effectively within an ambient temperature range of -25°C to +60°C, ensuring reliability in various environments.

How does the Type B tripping characteristic affect its performance?


The Type B tripping characteristic is designed to trip under moderate overload conditions, making it suitable for typical inductive loads without nuisance tripping, thereby enhancing operational reliability.

What are the installation requirements for this product?


The device is designed for DIN rail mounting, facilitating straightforward installation within electrical panels, which helps to save space and enhance organisation.

What is the significance of the high breaking capacity?


A breaking capacity of 50kA allows this MCB to interrupt higher fault currents safely, protecting circuits from potential damage due to short circuits and overloads, thus increasing system safety.