Honeywell GLD Series Roller Lever Limit Switch, SPDT, IP66, Fibreglass Reinforced Thermoplastic Housing, 240V ac, 10A
- RS庫存編號:
- 808-3163
- 製造零件編號:
- GLDA01A1B
- 製造商:
- Honeywell
可享批量折扣
小計(1 件)*
TWD2,143.00
(不含稅)
TWD2,250.15
(含稅)
庫存資訊目前無法存取 - 請稍後再回來查看
單位 | 每單位 |
|---|---|
| 1 - 12 | TWD2,143.00 |
| 13 + | TWD2,079.00 |
* 參考價格
- RS庫存編號:
- 808-3163
- 製造零件編號:
- GLDA01A1B
- 製造商:
- Honeywell
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| Contact Configuration | SPDT | |
| IP Rating | IP66 | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | Screw | |
| Series | GLD | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Width | 30.5mm | |
| Standards/Approvals | EN, UL, RoHS, IEC, CSA, CE, CCC | |
| Length | 68.5mm | |
| Depth | 26.35mm | |
| Hazardous Area Certification | NO | |
| Mechanical Life | 10000000Cycles | |
| Conduit Entry | 1/2 in to 14 NPT | |
| Operating Force | 0.12Nm | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
Contact Configuration SPDT | ||
IP Rating IP66 | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type Screw | ||
Series GLD | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Width 30.5mm | ||
Standards/Approvals EN, UL, RoHS, IEC, CSA, CE, CCC | ||
Length 68.5mm | ||
Depth 26.35mm | ||
Hazardous Area Certification NO | ||
Mechanical Life 10000000Cycles | ||
Conduit Entry 1/2 in to 14 NPT | ||
Operating Force 0.12Nm | ||
Honeywell GLD Series Limit Switch, Roller Lever Actuator, IP66 - GLDA01A1B
This limit switch provides a compact, industrial-grade mechanical position sensing solution for automation and control systems. It employs a roller lever actuator to detect motion and transmit a discrete switching signal, designed for use in demanding environments where robust enclosure protection and defined switching behaviour are required.
Features and Benefits:
• SPDT snap-action contact offers clear single-pole changeover switching
• Rated for 10A enables handling of significant control currents
• IP66 fibreglass-reinforced enclosure resists dust and powerful jets
• Mechanical endurance of 10 million cycles supports long service intervals
• Operating range from −40 °C to 85 °C suits extreme temperature conditions
• Actuation force 16 N provides predictable trigger response under load
• Rated for 10A enables handling of significant control currents
• IP66 fibreglass-reinforced enclosure resists dust and powerful jets
• Mechanical endurance of 10 million cycles supports long service intervals
• Operating range from −40 °C to 85 °C suits extreme temperature conditions
• Actuation force 16 N provides predictable trigger response under load
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for safety interlocks on industrial guarding systems
• Used with motor starters for position feedback in hoists and lifts
• Can be used for limit detection on automation pick-and-place units
• Used for end-stop sensing in material handling equipment
• Ideal for safety interlocks on industrial guarding systems
• Used with motor starters for position feedback in hoists and lifts
• Can be used for limit detection on automation pick-and-place units
• Used for end-stop sensing in material handling equipment
What conduit entry options are available for cable installation?
The unit accepts a 1/2 in to 14 NPT conduit entry for standard threaded conduit connections.
How does the contact arrangement affect wiring flexibility?
The single-pole double-throw configuration allows selection between normally closed and normally open circuits for flexible control logic.
What voltages can the contacts switch for AC and DC loads?
The contacts are specified for switching at 240V AC and up to 250V DC to accommodate typical control and signal voltages.
What material is the housing and how does it influence durability?
The enclosure is MADE from fibreglass-reinforced thermoplastic, providing mechanical resilience and corrosion resistance in harsh settings.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell GLD Series Adjustable Roller Lever Limit Switch IP66 240
- Honeywell GLD Series Roller Lever Limit Switch IP66 240 V ac, 6 A
- Honeywell GLD Series Roller Lever Limit Switch IP66 240 V ac, 10 A
- Honeywell GLD Series Adjustable Roller Lever Limit Switch IP66 240
- Honeywell GLD Series Rod Limit Switch IP66 240 V ac, 6 A
- Honeywell GLD Series Plunger Limit Switch IP66 240 V ac, 6 A
- Honeywell GLD Series Rod Limit Switch IP66 240 V ac, 10 A
- Honeywell GLD Series Roller Plunger Limit Switch IP66 240 V ac, 6 A