Honeywell Technologies GLD Series Adjustable Roller Lever Limit Switch, DPST, IP66, Fibreglass Reinforced Thermoplastic
- RS庫存編號:
- 311-2308
- 製造零件編號:
- GLDB06A2B
- 製造商:
- Honeywell Technologies
暫時無法供應
抱歉,我們不知道何時會到貨。
替代產品
該產品我們目前不提供。 這是我們推薦的替代產品。
個
TWD11,589.00
(不含稅)
TWD12,168.45
(含稅)
- RS庫存編號:
- 311-2308
- 製造零件編號:
- GLDB06A2B
- 製造商:
- Honeywell Technologies
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell Technologies | |
| Product Type | Limit Switch | |
| Actuator Type | Adjustable Roller Lever | |
| IP Rating | IP66 | |
| Contact Configuration | DPST | |
| Housing Material | Fibreglass Reinforced Thermoplastic | |
| Contact Type | Slow Action | |
| Switching Current | 10A | |
| Terminal Type | Screw | |
| Series | GLD | |
| Minimum Operating Temperature | -40°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Depth | 26.35mm | |
| Width | 30.5mm | |
| Length | 68.5mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | PG13.5 | |
| Operating Force | 0.11Nm | |
| Mechanical Life | 10000000Cycles | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell Technologies | ||
Product Type Limit Switch | ||
Actuator Type Adjustable Roller Lever | ||
IP Rating IP66 | ||
Contact Configuration DPST | ||
Housing Material Fibreglass Reinforced Thermoplastic | ||
Contact Type Slow Action | ||
Switching Current 10A | ||
Terminal Type Screw | ||
Series GLD | ||
Minimum Operating Temperature -40°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Depth 26.35mm | ||
Width 30.5mm | ||
Length 68.5mm | ||
Hazardous Area Certification No | ||
Conduit Entry PG13.5 | ||
Operating Force 0.11Nm | ||
Mechanical Life 10000000Cycles | ||
- COO (Country of Origin):
- GB

Honeywell GLD Series Limit Switch, 10A Switching Current, IP66 - GLDB06A2B
This limit switch offers a Compact electromechanical solution for detecting position changes and controlling circuits in industrial systems. It is designed for environments where resilient enclosure materials and sealed ingress protection are required, and it provides reliable actuation using a roller lever mechanism suitable for conveyor systems, machinery end-stops and automated assemblies.
Features and Benefits:
• Fibreglass-reinforced thermoplastic housing improves chemical and wear resistance
• DPST slow-action contacts allow controlled switching of two circuits
• Electrical rating supports 10A at 240V AC for common industrial loads
• Screw terminals enable secure wiring connections for onsite maintenance
• Mechanical endurance achieves 10 million cycles for long service intervals
• Operating range from -40°C to 85°C suits harsh temperature applications
• DPST slow-action contacts allow controlled switching of two circuits
• Electrical rating supports 10A at 240V AC for common industrial loads
• Screw terminals enable secure wiring connections for onsite maintenance
• Mechanical endurance achieves 10 million cycles for long service intervals
• Operating range from -40°C to 85°C suits harsh temperature applications
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for actuator position sensing in automated gating systems
• Used with motor control panels for limit detection and safety interlocks
• Can be used for repetitive stroke monitoring in packaging equipment
• Suitable for retrofitting to industrial machinery with roller-actuated interfaces
• Ideal for actuator position sensing in automated gating systems
• Used with motor control panels for limit detection and safety interlocks
• Can be used for repetitive stroke monitoring in packaging equipment
• Suitable for retrofitting to industrial machinery with roller-actuated interfaces
What kind of conduit connection does it accept?
It accepts a PG13.5 conduit entry to simplify cable-gland mounting and conduit runs.
How does the actuator Interface with mechanical linkages?
The adjustable roller lever provides a configurable contact point for varied approach angles and travel, allowing alignment with mechanical linkages.
What Terminal arrangement is provided for electricians?
Terminals are screw type which permit firm clamping of conductors and rework during installation.
Which approvals cover use in regulated installations?
The device carries CCC, CE, CSA and UL approvals for compatibility with multiple certification frameworks.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell Technologies GLD Series Adjustable Roller Lever Limit Switch IP66, Fibreglass Reinforced
- Honeywell Technologies GLD Series Roller Plunger Limit Switch IP66
- Honeywell Technologies GLD Series Metal Roller Limit Switch IP66
- Honeywell Technologies GLD Series Plunger Limit Switch IP66 240V
- Honeywell Technologies GLD Series Roller Lever Limit Switch IP66
- Honeywell Technologies GLD Series Roller Lever Limit Switch IP66, Fibreglass Reinforced Thermoplastic
- Honeywell Technologies GLD Series Plunger Limit Switch IP66 240V
- Honeywell Technologies GLD Series Roller Plunger Limit Switch IP66, Fibreglass Reinforced Thermoplastic