Honeywell Technologies GLA Series Roller Lever Limit Switch, 2 NO/2 NC, IP67, Die Cast Zinc Epoxy Coated Housing, 600V
- RS庫存編號:
- 808-3117
- 製造零件編號:
- GLAA20A1B
- 製造商:
- Honeywell
小計(1 件)*
TWD11,840.00
(不含稅)
TWD12,432.00
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 10 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD11,840.00 |
* 參考價格
- RS庫存編號:
- 808-3117
- 製造零件編號:
- GLAA20A1B
- 製造商:
- Honeywell
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| IP Rating | IP67 | |
| Contact Configuration | 2 NO/2 NC | |
| Housing Material | Die Cast Zinc Epoxy Coated | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | Screw | |
| Series | GLA | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Maximum Operating Temperature | 85°C | |
| Length | 42mm | |
| Standards/Approvals | CSA, EN, IEC, RoHS, UL, CCC, CE | |
| Depth | 82mm | |
| Width | 42mm | |
| Hazardous Area Certification | No | |
| Mechanical Life | 15000000Operations | |
| Mounting Orientation | Side | |
| Operating Force | 0.33Nm | |
| Conduit Entry | 0.5 to 14 NPT | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
IP Rating IP67 | ||
Contact Configuration 2 NO/2 NC | ||
Housing Material Die Cast Zinc Epoxy Coated | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type Screw | ||
Series GLA | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Maximum Operating Temperature 85°C | ||
Length 42mm | ||
Standards/Approvals CSA, EN, IEC, RoHS, UL, CCC, CE | ||
Depth 82mm | ||
Width 42mm | ||
Hazardous Area Certification No | ||
Mechanical Life 15000000Operations | ||
Mounting Orientation Side | ||
Operating Force 0.33Nm | ||
Conduit Entry 0.5 to 14 NPT | ||
- COO (Country of Origin):
- GB
Honeywell GLA Series Limit Switch, 10A Switching Current, IP67 - GLAA20A1B
This limit switch offers robust switching for industrial automation and control tasks, delivering snap-action contact operation via a roller lever actuator. It is housed in a die-cast zinc enclosure with ingress protection suitable for harsh environments, and supports side mounting for integration into mechanical systems.
Features and Benefits:
• 2NO and 2NC contacts provide versatile signalling options
• Snap-action contacts enable fast, repeatable switching performance
• Rated for 10A switching current to handle moderate loads
• Operates up to 600VAC for high-voltage control circuits
• Mechanical life of 15 million operations reduces replacement frequency
• Temperature range from -25 to 85°C maintains function in extremes
• Snap-action contacts enable fast, repeatable switching performance
• Rated for 10A switching current to handle moderate loads
• Operates up to 600VAC for high-voltage control circuits
• Mechanical life of 15 million operations reduces replacement frequency
• Temperature range from -25 to 85°C maintains function in extremes
Applications
• Suitable for position sensing on automated conveyors
• Ideal for end-of-travel detection in electric actuators
• Used with industrial Gates and safety interlocks
• Can be used for limit detection in assembly lines
• Used for signalling in motor control cabinets
• Ideal for end-of-travel detection in electric actuators
• Used with industrial Gates and safety interlocks
• Can be used for limit detection in assembly lines
• Used for signalling in motor control cabinets
What conduit entry options are available for installation?
The unit accepts 1/2-14 NPT conduit fittings to accommodate standard threaded wiring connections.
How is mounting orientation constrained for integration?
It is designed for side mounting to align the roller lever with lateral actuating elements.
Which approvals support use in regulated installations?
Certification includes CSA, EN, IEC, RoHS, UL, CCC and CE, indicating compliance with multiple regional standards.
What construction protects against mechanical impact and corrosion?
The enclosure is MADE from die-cast zinc, offering structural strength and environmental resistance.
How does the switch perform electrically on DC circuits?
It is rated for switching up to 250VDC, enabling use in DC control and signalling applications.
Approvals
UL/ UL listed for Canada
Warning
GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 10A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac
- Honeywell GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 10A