Honeywell Technologies GLA Series Roller Lever Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A

小計(1 件)*

TWD8,465.00

(不含稅)

TWD8,888.25

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 25 件從 2026年10月19日 起裝運發貨
  • 加上 28 件從 2026年11月02日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD8,465.00

* 參考價格

RS庫存編號:
186-8245
製造零件編號:
GLAC01D
製造商:
Honeywell
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Honeywell

Actuator Type

Roller Lever

Product Type

Limit Switch

IP Rating

IP67

Contact Configuration

DPDT

Housing Material

Die Cast Zinc Epoxy Coated

Contact Type

Snap Action

Switching Current

6A

Terminal Type

M20

Series

GLA

Switching DC Voltage

250V dc

Switching AC Voltage

600V ac

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Width

42mm

Standards/Approvals

UL, CSA, CE, CCC

Length

145.8mm

Depth

42mm

Hazardous Area Certification

No

Mechanical Life

15000000Cycles

Conduit Entry

20 mm

Operating Force

9.5N

COO (Country of Origin):
GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, Die Cast Zinc Housing - GLAC01D


This limit switch provides precise mechanical position detection for industrial control systems, employing a roller lever actuator to convert motion into electrical signals. It is intended for use in automation and machinery where robust switching and environmental protection are required.

Features and Benefits:


• DPDT snap‑action contacts deliver reliable changeover switching
• Rated switching AC voltage 600V for high‑voltage applications
• Switching DC capability up to 250V at 6A for control circuits
• Enclosure constructed from die‑cast zinc offering sturdy protection
• IP67 ingress protection enables use in wet or dusty environments
• Mechanical endurance of 15 000 000 cycles reduces maintenance frequency
• Actuation force 9.5 N ensures consistent operation under load

Applications


• Suitable for conveyor end‑of‑travel detection in manufacturing lines
• Ideal for position sensing in automated assembly equipment
• Used with safety interlocks on access panels and guards
• Can be used for limit detection in material‑handling systems
• Used for feedback on actuated valves and dampers in HVAC controls

What conduit connection is provided for wiring?


A threaded M20 conduit entry is supplied for cable glands and conduit fittings.

What temperature range will the switch operate within?


It operates between −25 °C and 85 °C for standard industrial environments.

Which contact arrangement is fitted and how does it affect wiring?


A double‑pole double‑throw contact set permits switching of two independent circuits or changeover configurations.

Which approvals cover the device for industrial use?


It is certified to UL, CSA, CE and CCC standards for recognised safety and performance.

Approvals

UL/ UL listed for Canada

Warning

GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.