Honeywell Technologies GLC Series Roller Lever Limit Switch, 1 NC/1 NO, IP66, Die Cast Zinc Housing, 240V ac, 6A
- RS庫存編號:
- 308-1945
- 製造零件編號:
- GLCB07A1B
- 製造商:
- Honeywell Technologies
小計(1 件)*
TWD4,268.00
(不含稅)
TWD4,481.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 127 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD4,268.00 |
* 參考價格
- RS庫存編號:
- 308-1945
- 製造零件編號:
- GLCB07A1B
- 製造商:
- Honeywell Technologies
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Honeywell Technologies | |
| Actuator Type | Roller Lever | |
| Product Type | Limit Switch | |
| IP Rating | IP66 | |
| Contact Configuration | 1 NC/1 NO | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 6A | |
| Series | GLC | |
| Switching AC Voltage | 240V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | UL, CE, CCC, CSA | |
| Depth | 26.35mm | |
| Width | 30.5mm | |
| Length | 68.5mm | |
| Hazardous Area Certification | No | |
| Mounting Orientation | Vertical | |
| Mechanical Life | 10000000Cycles | |
| Operating Force | 0.12Nm | |
| Conduit Entry | PG13.5 | |
| 選取全部 | ||
|---|---|---|
品牌 Honeywell Technologies | ||
Actuator Type Roller Lever | ||
Product Type Limit Switch | ||
IP Rating IP66 | ||
Contact Configuration 1 NC/1 NO | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 6A | ||
Series GLC | ||
Switching AC Voltage 240V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals UL, CE, CCC, CSA | ||
Depth 26.35mm | ||
Width 30.5mm | ||
Length 68.5mm | ||
Hazardous Area Certification No | ||
Mounting Orientation Vertical | ||
Mechanical Life 10000000Cycles | ||
Operating Force 0.12Nm | ||
Conduit Entry PG13.5 | ||
- COO (Country of Origin):
- GB



Honeywell GLC Series Limit Switch, IP66, 6A Switching Current - GLCB07A1B
This limit switch provides positional detection and circuit control for industrial automation and machine safety tasks. Fitted with a roller lever actuator and a snap-action contact mechanism, it is engineered for repeated actuation in demanding electrical and mechanical systems. Its sealed enclosure and conduit entry enable use in harsher environments while maintaining clear switching behaviour for control circuits.
Features and Benefits:
• Snap-action contacts for consistent fast switching performance
• 1NC and 1NO contacts to support versatile control logic
• Rated for 6A current at 240V AC for mains switching tasks
• Operating range from −40°C to 85°C for extreme-temperature applications
• Mechanical endurance up to 10,000,000 cycles for long service intervals
• IP66 enclosure for protection against dust and powerful water jets
• 1NC and 1NO contacts to support versatile control logic
• Rated for 6A current at 240V AC for mains switching tasks
• Operating range from −40°C to 85°C for extreme-temperature applications
• Mechanical endurance up to 10,000,000 cycles for long service intervals
• IP66 enclosure for protection against dust and powerful water jets
Applications
• Suitable for conveyor end-of-travel detection in factories
• Ideal for limit sensing on packaging and assembly machinery
• Used with motor starters for safety interlock functions
• Can be used for position feedback in automated Gates and doors
• Used for actuator end-stop detection in material handling systems
• Ideal for limit sensing on packaging and assembly machinery
• Used with motor starters for safety interlock functions
• Can be used for position feedback in automated Gates and doors
• Used for actuator end-stop detection in material handling systems
What conduit connection is provided for cable entry?
The unit accepts a PG13.5 conduit fitting to secure incoming cables and glands for sealed wiring.
How is the enclosure constructed to withstand industrial use?
The housing is formed from zinc with an electrostatic epoxy coating to resist corrosion and surface wear.
How should the switch be mounted for correct operation?
It is designed for vertical mounting to ensure proper actuation geometry with the roller lever.
What switching voltages can the contacts handle?
The contacts are suitable for switching up to 240V AC and up to 250V DC within the rated current.
Approvals
UL/ UL listed for Canada
Warning
GLC and GLD limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
相關連結
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Rotary Lever Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP67 240V ac, 6A
- Honeywell Technologies GLC Series Plunger Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP66 240V ac,
- Honeywell Technologies GLC Series Roller Lever Limit Switch IP67 300V
- Honeywell Technologies GLC Series Rod Limit Switch IP66 240V ac, 6A
- Honeywell Technologies GLC Series Plunger Limit Switch IP66 240V ac, 6A
