Honeywell Technologies GLA Series Plunger Limit Switch, DPDT, IP67, Die Cast Zinc Epoxy Coated Housing, 600V ac, 6A

小計(1 件)*

TWD10,646.00

(不含稅)

TWD11,178.30

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 12 件從 2026年12月14日 起裝運發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD10,646.00

* 參考價格

RS庫存編號:
223-3218
製造零件編號:
GLAC20B
製造商:
Honeywell
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Honeywell

Product Type

Limit Switch

Actuator Type

Plunger

IP Rating

IP67

Contact Configuration

DPDT

Housing Material

Die Cast Zinc Epoxy Coated

Contact Type

Snap Action

Switching Current

6A

Terminal Type

M20

Series

GLA

Switching DC Voltage

250V dc

Minimum Operating Temperature

-25°C

Switching AC Voltage

600V ac

Maximum Operating Temperature

85°C

Width

42mm

Length

145.8mm

Standards/Approvals

CE, CSA, UL, CCC

Depth

42mm

Hazardous Area Certification

No

Mechanical Life

15000000Cycles

Conduit Entry

20 mm

Operating Force

16N

COO (Country of Origin):
GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, DPDT Contact Configuration - GLAC20B


This limit switch is a mechanically operated device designed to detect position changes and provide control signals in industrial systems. It uses a plunger actuator to convert physical movement into electrical switching, and is built with a die-cast zinc enclosure and sealed construction for demanding environments. The unit offers double-pole double-throw switching and is suited to applications where snap-action contact behaviour and robustness are required.

Features and Benefits:


• DPDT contact arrangement enables flexible circuit control
• Snap-action contacts deliver Rapid switching response
• Rated for 6A at 600V AC for common industrial loads
• Die-cast zinc housing affords rugged environmental protection
• IP67 sealing permits use in wet and dusty conditions
• Mechanical endurance of 15 million cycles supports long service life

Applications


• Suitable for conveyor end-of-travel detection in factories
• Ideal for limit sensing on industrial presses and actuators
• Used for position feedback in automated assembly lines
• Can be used for safety interlocks on machine guards
• Suitable for control panels requiring M20 conduit entry

What electrical voltages can it switch for DC circuits?


It can switch DC voltages up to 250V in appropriate circuit configurations.

How does the actuator operate under high-temperature conditions?


The plunger actuator functions across an ambient range from -25°C up to 85°C without compromising switching action.

What conduit connection is provided for wiring?


The unit accepts an M20 conduit entry for standard industrial cable glands and conduit fittings.

Are there recognised approvals for industrial deployment?


It carries CE, CSA, UL and CCC approvals indicating conformity with multiple regional standards.

What type of Terminal Interface does it use?


Termination is provided via an M20-style Terminal arrangement suitable for secure electrical connections.

Approvals

UL/ UL listed for Canada

Warning

GLA limit switches have not been designed as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of the products failing.

Standards

IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.

EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).

IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.

Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。