ABB Light Curtain Receiver, Sender, 16 Beam(s), 30 mm Resolution

小計(1 套)*

TWD42,894.00

(不含稅)

TWD45,038.70

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年11月24日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
對
每對
1 +TWD42,894.00

* 參考價格

RS庫存編號:
920-9694
製造零件編號:
2TLA022302R0100 Orion1-4-30-030-B
製造商:
ABB
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

ABB

Product Type

Light Curtain

Beam Resolution

30mm

Component Type

Receiver, Sender

Safety Type

4

Standards/Approvals

e

Number of Beams

16

Protective Height

300mm

Maximum Protective Width

19m

Maximum Supply Voltage

24V dc

Minimum Scanning Distance

0.2m

Maximum Scanning Distance

19m

Maximum Response Time

11ms

Length

383mm

Height

37mm

Width

32.3mm

Terminal Type

M12 Connector

COO (Country of Origin):
IT

ABB Orion1 Light Curtains


The Orion1 light curtains from ABB are supplied with a transmitter and receiver. They can be installed close to a dangerous machine and are designed for finger or hand detection. The Orion1 is available in two options, a base model and an extended model.

Features and Benefits


No more functions or settings than necessary

A local reset button can be connected directly to the light curtain: no need for cable between the reset button and the electrical cabinet or for an extra control module.

Each light curtain can monitor the actuators without any extra control module (EDM function)

Alignment help and a wide angle within the limits of a Type 4 device facilitate alignment

Rotation brackets simplify alignment too

M12 connectors speed up cabling

The alignment level being displayed, the alignment can be improved before the occurrence of the unwanted stop

Extensive error indication reduces troubleshooting time

Protective tubes and lens shields protect the devices in harsh environments

Muting sensors are connected directly to the extended model, with no need for a remote extra muting module

6 m and 19 m operating distances (finger and hand detection)

Compact dimensions

Applications


Finger and hand detection

When the light guard is required to be close to the hazardous zone

When repeated access to the machine is necessary, manually serviced machines for example

For area protection (horizontal mounting) and limitation of work zones

Light Curtain


Note

Both the base and extended models provide detection, local reset and external device monitoring (EDM), but the extended model also provides muting.

Approvals

CE, cULus, TUV.

Standards

EN ISO 13849-1:2008 PL e, Cat 4
EN 61508-1..4:2010 SIL3
EN 62061:2005/A1:2013 SIL CL 3

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。