SICK C40S Series Light Curtain Sender, 40 mm Resolution

小計(1 件)*

TWD68,366.00

(不含稅)

TWD71,784.30

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月01日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD68,366.00

* 參考價格

RS庫存編號:
285-0978
製造零件編號:
C40S-0904CA010
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Light Curtain

Series

C40S

Beam Resolution

40mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

21m

Length

48mm

Height

1.03m

Width

40mm

COO (Country of Origin):
DE

SICK C40S Series Light Curtain, 1.03m Protective Height, 24V Supply Voltage - C40S-0904CA010


This light curtain is a safety sender designed for industrial environments to protect personnel and machinery by detecting intrusions into a guarded zone. It operates from a 24V supply and uses optical synchronisation for emitter-receiver pairing, supporting long-range monitoring. The device is intended for integration with safety relay systems and can be deployed where defined protective fields are required.

Features and Benefits:


• 21m scanning range provides extended monitoring distance
• 40mm beam resolution permits coarse object detection over area
• Type 4 safety classification ensures high-level risk reduction
• SIL 3 and PL e achieve stringent functional safety targets
• Optical synchronisation reduces cross-talk between units

Applications


• Suitable for machine guarding on production lines
• Used with safety relays for restart interlock functions
• Ideal for guarding long conveyor sections
• Can be used for access protection in automated cells
• Used with external device monitoring and bypass schemes

What environmental limits affect its installation?


It operates between 0°C and +55°C and withstands non‑condensing humidity of 15%-95%.

How is the device physically constructed for mounting?


The housing is an extruded aluminium profile with a 48mm x 40mm cross-section and specific sliding‑nut grooves for side mounting.

What electrical connection and protection class apply?


It requires a 24V DC supply (19.2V to 28.8V range) and meets Protection Class III requirements.

What failure behaviour is defined for safety outputs?


On fault at least one OSSD is driven to the OFF state to ensure a safe condition.