SICK C40S Series Light Curtain Sender, 14 mm Resolution

小計(1 件)*

TWD94,550.00

(不含稅)

TWD99,277.50

(含稅)

Add to Basket
選擇或輸入數量
製造商存貨
  • 準備從 2026年12月21日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD94,550.00

* 參考價格

RS庫存編號:
285-0976
製造零件編號:
C40S-0901CA010
製造商:
SICK
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

SICK

Product Type

Light Curtain

Series

C40S

Beam Resolution

14mm

Component Type

Sender

Safety Type

Type 4

Standards/Approvals

ACMA, CE, cUL, EC-Type-Examination, GB, GB/T, IEC, Moroccan, OSHA, RoHS, UKCA, cULus

Protective Height

900mm

Maximum Supply Voltage

24V

Maximum Scanning Distance

10m

Height

1.03m

Width

40mm

Length

48mm

COO (Country of Origin):
DE

SICK C40S Series Light Curtain, 24V Maximum Supply Voltage, 900mm protective height - C40S-0901CA010


This light curtain is a safety sensor designed for industrial environments to protect personnel and machinery by creating a monitored protective field. It functions as the sender component within a system, employing optical synchronisation and offering a configurable scanning range suitable for short- to medium-reach installations. The unit operates from a 24V supply and is intended for integration with safety relays and control equipment.

Features and Benefits:


• 14mm beam resolution provides fine object detection and precise protection
• 10m scanning distance enables extended coverage for larger machines
• Type 4 safety classification delivers high risk reduction and fault tolerance
• IP65 enclosure rating permits use in dusty and damp conditions
• Aluminium housing reduces weight and supports Durable mounting

Applications


• Suitable for safeguarding production line access points
• Ideal for integration with safety relays in machine cells
• Used with palletising systems requiring optically synchronised sensing
• Can be used for protecting automated handling equipment
• Suitable for retrofit safety upgrades in manufacturing plants

What safety performance levels does it meet?


It meets SIL3, Category 4 and PL e as defined by IEC/EN standards.

How is the unit synchronised with its counterpart?


Synchronisation is achieved optically between sender and receiver.

What environmental conditions can it tolerate?


It operates between 0°C and +55°C with 15%-95% non‑condensing humidity and withstands vibration and shock per relevant EN tests.

What electrical supply requirements exist for operation?


It requires 24V DC (19.2V to 28.8V) with supply buffering for 20 MS disturbances.

How does the device indicate status and faults?


Local 7‑segment display elements are provided and LEDs indicate operational states and contamination alerts.

相關連結

第一時間了解我們的最新產品和優惠