Delta-Mobrey Gap Sensor Level Switch, Horizontal, Vertical, NO-Rated, Housing Polyphenylene Sulphide
- RS庫存編號:
- 204-6749
- 製造零件編號:
- 003S2
- 製造商:
- Delta-Mobrey
小計(1 件)*
TWD8,966.00
(不含稅)
TWD9,414.30
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 93 件準備從其他地點送貨
- 加上 66 件從 2026年5月28日 起發貨
- 加上 62 件從 2026年6月04日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD8,966.00 |
* 參考價格
- RS庫存編號:
- 204-6749
- 製造零件編號:
- 003S2
- 製造商:
- Delta-Mobrey
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Delta-Mobrey | |
| Device Type | Gap Sensor | |
| Product Type | Level Switch | |
| Mount Type | Horizontal, Vertical | |
| Housing Material | Polyphenylene Sulphide | |
| Cable Length | 3m | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 70°C | |
| Maximum DC Voltage | 30V dc | |
| Maximum Current | 1A | |
| Maximum Pressure | 5bar | |
| Standards/Approvals | No | |
| Hazardous Area Certification | NO | |
| 選取全部 | ||
|---|---|---|
品牌 Delta-Mobrey | ||
Device Type Gap Sensor | ||
Product Type Level Switch | ||
Mount Type Horizontal, Vertical | ||
Housing Material Polyphenylene Sulphide | ||
Cable Length 3m | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 70°C | ||
Maximum DC Voltage 30V dc | ||
Maximum Current 1A | ||
Maximum Pressure 5bar | ||
Standards/Approvals No | ||
Hazardous Area Certification NO | ||



Mobrey Level Switch
The Mobrey ultrasonic liquid level switch with polyphenylene sulphide construction has output type integral SPCO relay (energised when the sensor is wet) and 1-in BSPT dual mount thread. This switch is designed for high or low-level alarm duties to give a voltage-free contact or solid-state transistor output for alarm signalling or as part of a pump control system. It is intended for level detection at a fixed point when liquid fills the gap between the crystals. The supply voltage ranges between 18VAC/DC and 30VAC/DC
Note:
If the liquid to be monitored is flowing, the device should be fitted with the gap inline with the flow. In storage tanks, it should be fitted with the gap vertical unless the liquid is highly aerated when it should be angled.
Features and Benefits
Vessel pressure of 5bar (maximum)
Wet switching level detection at a fixed point when liquid fills the gap between the crystals
Switched voltage is 30VDC (maximum)
Suitable for low maintenance applications
High reliability with no moving parts
Not easily subject to fouling and not affected by ambient light conditions
Fitted with three metres of cable
Lightweight
No moving parts
Mounting types are horizontal and vertical
Applications
Low level alarms in header tanks
Pump control duty in feeder tanks
High and low alarms in storage tanks
Level and pump control in storage tanks
Small or thin wall tanks
Bund level detection
Steering gear oil
Certifications
NEMA 6P (10ft.)/IP66/IP68 (3m)
相關連結
- Delta-Mobrey Gap Sensor Level Switch Horizontal, Housing Polyphenylene Sulphide
- Delta-Mobrey VLS Series Solids Level Switch Level Switch Horizontal Non-Asbestos Sheet, Housing
- RS PRO JC2M Series Ultrasonic Level Sensor Housing Polyphenylene Sulphide
- Sensata / Cynergy3 RSF70 Series Float Level Switch Housing Polyphenylene Sulphide
- Siemens Round Polyphenylene Sulphide Spacer 6GT26900AA00 85 mm
- Delta-Mobrey Liquid Level Switch Level Switch Non-Asbestos Sheet, Housing Aluminium Bronze
- Endress+Hauser FTC262 Series Point Level Level Sensor ATEX-Rated, Housing Polyphenylene Sulphide