Fluke 1535 Insulation Resistance Tester, 250 V Min, 2500 V Max, 500 GΩ CAT IV
- RS庫存編號:
- 283-7401
- Distrelec 貨號:
- 304-20-196
- 製造零件編號:
- FLUKE-1535
- 製造商:
- Fluke
小計(1 件)*
TWD57,750.00
(不含稅)
TWD60,637.50
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 5 件準備從其他地點送貨
- 加上 3 件從 2026年6月18日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD57,750.00 |
* 參考價格
- RS庫存編號:
- 283-7401
- Distrelec 貨號:
- 304-20-196
- 製造零件編號:
- FLUKE-1535
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Insulation Tester | |
| Model Number | 1535 | |
| Tester Type | Insulation Resistance Tester | |
| Maximum Test Voltage | 2500V | |
| Minimum Test Voltage | 250V | |
| Display Type | LCD | |
| Test Current | 5mA | |
| Battery Type | AA Alkaline | |
| Power Source | Battery | |
| Insulation Testing Resistance | 500GΩ | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Voltage | 600V | |
| Safety Category Level | CAT IV | |
| Length | 93mm | |
| Height | 184mm | |
| Width | 211mm | |
| Standards/Approvals | Pollution Degree 2 IEC 615571, IEC 610101 | |
| Weight | 1.3kg | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Insulation Tester | ||
Model Number 1535 | ||
Tester Type Insulation Resistance Tester | ||
Maximum Test Voltage 2500V | ||
Minimum Test Voltage 250V | ||
Display Type LCD | ||
Test Current 5mA | ||
Battery Type AA Alkaline | ||
Power Source Battery | ||
Insulation Testing Resistance 500GΩ | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Safety Category Voltage 600V | ||
Safety Category Level CAT IV | ||
Length 93mm | ||
Height 184mm | ||
Width 211mm | ||
Standards/Approvals Pollution Degree 2 IEC 615571, IEC 610101 | ||
Weight 1.3kg | ||
- COO (Country of Origin):
- CN
Fluke Insulation Tester, 500GΩ Insulation Testing Resistance, 2500V Maximum Test Voltage - FLUKE-1535
This insulation tester is a portable handheld diagnostic instrument designed for field and workshop insulation resistance assessment across industrial and renewable-energy settings. It delivers selectable test voltages from 250V to 2500V and measures very high resistance values to assist technicians in verifying insulation integrity and locating degradation on electrical assets.
Features & Benefits
• Selectable voltages 250–2500V for tailored testing ranges
• Insulation measurement capability up to 500GΩ for high‑resistance detection
• Short‑circuit current up to 5mA for faster, stable readings
• CAT IV 600V safety rating for use near incoming supply points
• AA battery operation enabling long field use without mains power
• LCD display for clear visualisation of measured values
• Insulation measurement capability up to 500GΩ for high‑resistance detection
• Short‑circuit current up to 5mA for faster, stable readings
• CAT IV 600V safety rating for use near incoming supply points
• AA battery operation enabling long field use without mains power
• LCD display for clear visualisation of measured values
**Applications**
• Suitable for insulation testing of motors and generators on site
• Ideal for commissioning and maintenance of solar installations
• Used for preventive maintenance in industrial electrical systems
• Can be used for troubleshooting insulation faults on factory equipment
• Ideal for commissioning and maintenance of solar installations
• Used for preventive maintenance in industrial electrical systems
• Can be used for troubleshooting insulation faults on factory equipment
How many measurements can I expect between battery changes?
Using AA alkaline cells, the unit can perform over 1,300 tests at the highest test voltage on a single set of batteries.
Are there functions to assist insulation condition analysis?
Yes. It calculates Polarisation Index and Dielectric Absorption Ratio automatically to reduce environmental influence on results.
What additional measurements does the Advanced variant offer?
The Advanced instrument provides AC/DC voltage and resistance measurements Plus adjustable test voltage in 100V steps and ramp test mode.
How does the instrument manage charged capacitive circuits?
Charging and discharging behaviour is specified
typical charge rate for capacitive loads is 5s/μF and discharge rate is 1.5s/μF.
相關連結
- Fluke 1537 Insulation Tester 2500 V Max, 500 GΩ CAT IV
- Fluke 1577 Insulation Tester 1000 V Max CAT IV
- Fluke 1507 Insulation Tester 1000 V Max CAT IV
- Megger MIT2500 Insulation Tester 2500 V Max, 200 GΩ CAT IV
- Fluke 1550C Insulation Tester 5000 V Max CAT IV, CAT III
- Fluke 1503 Insulation Tester 1000 V Max CAT III
- Fluke 1587 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1550C FC Insulation Tester 5000 V Max CAT III, CAT IV