Alpha Wire Ecogen Ecowire Series Slate 0.2 mm² Hook Up Wire, 24 AWG, 7, 30 m, Modified Polyphenylene Ether, 6712 WH005
- RS庫存編號:
- 687-7427
- Distrelec 貨號:
- 300-59-329
- 製造零件編號:
- 6712 WH005
- 製造商:
- Alpha Wire
可享批量折扣
小計(1 卷,共 30 米)*
TWD1,958.00
(不含稅)
TWD2,055.90
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 17 件從 2026年4月13日 起發貨
- 加上 47 件從 2026年5月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 - 49 | TWD1,958.00 | TWD65.267 |
| 50 + | TWD1,912.00 | TWD63.733 |
* 參考價格
- RS庫存編號:
- 687-7427
- Distrelec 貨號:
- 300-59-329
- 製造零件編號:
- 6712 WH005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Cross Sectional Area | 0.2mm² | |
| Product Type | Hook Up Wire | |
| Jacket Colour | Slate | |
| American Wire Gauge | 24AWG | |
| Core Strands | 7 | |
| Cable Length | 30m | |
| Voltage | 600V | |
| Outside Diameter | 1.09mm | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Standards/Approvals | CE, CSA, UL | |
| Jacket Material | Modified Polyphenylene Ether | |
| Minimum Operating Temperature | -40°C | |
| Fire Behaviour | Flame Retardant, Halogen Free, Low Outgassing | |
| Series | Ecogen Ecowire | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Cross Sectional Area 0.2mm² | ||
Product Type Hook Up Wire | ||
Jacket Colour Slate | ||
American Wire Gauge 24AWG | ||
Core Strands 7 | ||
Cable Length 30m | ||
Voltage 600V | ||
Outside Diameter 1.09mm | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Standards/Approvals CE, CSA, UL | ||
Jacket Material Modified Polyphenylene Ether | ||
Minimum Operating Temperature -40°C | ||
Fire Behaviour Flame Retardant, Halogen Free, Low Outgassing | ||
Series Ecogen Ecowire | ||
- COO (Country of Origin):
- MX
Belden Ecogen Ecowire Series Hook Up Wire, 0.2mm² Cross Sectional Area, Unshielded Type - 6712 WH005
This hook up wire is designed for reliable electrical connections in a variety of applications. With a cross-sectional area of 0.2mm², this 24 AWG wire features a single core construction and is insulated with modified polyphenylene ether (MPPE). The wire has an outer diameter of 1.09mm and is provided in a length of 30m, ensuring versatility for multiple installations and connections.
Features & Benefits
• Provides strong electrical conductivity with tinned copper material
• Rated for high voltages up to 600V for safety in applications
• Suitable for operating temperatures from -40 to +105°C
• Insulated with durable MPPE for enhanced performance
• Meets rigorous CE, CSA, and UL standards for quality assurance
• Unshielded design allows for straightforward installation and flexibility
Applications
• Used for wiring in electrical and mechanical systems
• Ideal for automation projects requiring durable connections
• Suitable for electronics where high-temperature performance is critical
• Utilised in control panels and circuitry in various machinery
What advantages does the use of tinned copper provide in this wire?
Tinned copper enhances resistance to corrosion and oxidation, which is essential for maintaining conductivity over time, particularly in humid or harsh environments. This prolongs the life of the electrical connections made using the wire.
How does this wire perform under varying temperature conditions?
Designed to function effectively within a temperature range of -40 to +105°C, it ensures consistent performance in both extremely cold and hot environments, making it suitable for diverse applications.
What specifications should I consider for compliance with industry standards?
This wire is compliant with several standards including CE, CSA, and UL, making it a dependable choice for users requiring adherence to safety and quality regulations in the electrical industry.
What is the significance of the wire's inductance and conductor resistance?
The nominal inductance rating of 0.05 μH/ft and conductor DCR of 25 Ω/1000ft at 20°C indicate its minimal signal loss, ensuring effective transmission in complex wiring setups without performance degradation.
Can the wire's insulation withstand exposure to flames?
Yes, the MPPE insulation adheres to IEC 60332-2 standards for flame behaviour, providing an added layer of safety by reducing the risk of fire hazards in electrical installations.
相關連結
- Alpha Wire Ecogen Ecowire Series Slate 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether,
- Alpha Wire Ecogen Ecowire Series Slate 0.75 mm² Hook Up Wire 16 Modified Polyphenylene Ether,
- Alpha Wire Ecogen Ecowire Series Green 24 AWG 30 m 6712
- Alpha Wire Ecogen Ecowire Series Purple 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6712 VI001
- Alpha Wire Ecogen Ecowire Series Red 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6712 RD001
- Alpha Wire Ecogen Ecowire Series Brown 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6712 BR005
- Alpha Wire Ecogen Ecowire Series Yellow 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6712 YL001
- Alpha Wire Ecogen Ecowire Series White 0.2 mm² Hook Up Wire 7 Modified Polyphenylene Ether, 6712 WH001
