Alpha Wire Ecogen Ecowire Series Yellow 0.2 mm² Hook Up Wire, 24 AWG, 7, 30 m, Modified Polyphenilether, 6712 YL005
- RS庫存編號:
- 687-7437
- 製造零件編號:
- 6712 YL005
- 製造商:
- Alpha Wire
可享批量折扣
小計(1 卷,共 30 米)*
TWD1,988.00
(不含稅)
TWD2,087.40
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 9 件準備從其他地點送貨
- 加上 23 件從 2026年7月07日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
卷 | 每卷 | 每米* |
|---|---|---|
| 1 - 49 | TWD1,988.00 | TWD66.267 |
| 50 + | TWD1,890.00 | TWD63.00 |
* 參考價格
- RS庫存編號:
- 687-7437
- 製造零件編號:
- 6712 YL005
- 製造商:
- Alpha Wire
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Alpha Wire | |
| Cross Sectional Area | 0.2mm² | |
| Product Type | Hook Up Wire | |
| Jacket Colour | Yellow | |
| American Wire Gauge | 24AWG | |
| Core Strands | 7 | |
| Cable Length | 30m | |
| Outside Diameter | 1.09mm | |
| Voltage | 600V | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Standards/Approvals | CE, CSA, UL | |
| Jacket Material | Modified Polyphenilether | |
| Cable Type | Hookup | |
| Minimum Operating Temperature | -40°C | |
| Sub Type | EcoWire | |
| Fire Behaviour | Halogen Free | |
| Series | Ecogen Ecowire | |
| 選取全部 | ||
|---|---|---|
品牌 Alpha Wire | ||
Cross Sectional Area 0.2mm² | ||
Product Type Hook Up Wire | ||
Jacket Colour Yellow | ||
American Wire Gauge 24AWG | ||
Core Strands 7 | ||
Cable Length 30m | ||
Outside Diameter 1.09mm | ||
Voltage 600V | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Standards/Approvals CE, CSA, UL | ||
Jacket Material Modified Polyphenilether | ||
Cable Type Hookup | ||
Minimum Operating Temperature -40°C | ||
Sub Type EcoWire | ||
Fire Behaviour Halogen Free | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 0.2mm² Cross Sectional Area, Yellow - 6712 YL001
This hook-up wire is a flexible single-core cable designed for general-purpose electrical connections in industrial and electronic systems. It provides insulated copper conductors for signal and power interconnections where a compact, colour-coded lead is required, and is suited to installations requiring elevated temperature performance.
Features & Benefits
• 0.2mm² conductor offers Compact cross section for tight routing
• 7-strand construction delivers enhanced flexibility for frequent movement
• 600Vrms rating allows use on low-voltage power and control circuits
• Temperature range -40°C to 105°C supports hot-environment operation
• VW-1 and IEC 60332-2 flame behaviour reduces fire spread risk
• Modified polyphenylene ether jacket provides halogen-free insulation
• 7-strand construction delivers enhanced flexibility for frequent movement
• 600Vrms rating allows use on low-voltage power and control circuits
• Temperature range -40°C to 105°C supports hot-environment operation
• VW-1 and IEC 60332-2 flame behaviour reduces fire spread risk
• Modified polyphenylene ether jacket provides halogen-free insulation
**Applications**
• Suitable for wiring control panels in automation equipment
• Ideal for internal wiring of electronic devices and instruments
• Used for field terminations in machinery harnesses
• Can be used for interconnects in electrical assemblies on machines
• Ideal for internal wiring of electronic devices and instruments
• Used for field terminations in machinery harnesses
• Can be used for interconnects in electrical assemblies on machines
What conductor composition ensures conductivity and pliability?
The conductor is copper MADE up of seven strands, combining electrical conductivity with improved flexibility compared with a solid core.
How is the product packaged for continuous installation runs?
It is supplied on spools offering continuous lengths such as 100 ft and 1,000 ft to aid uninterrupted cable pulls.
How does the insulation support regulatory and environmental requirements?
The jacket is halogen-free modified polyphenylene ether and the construction complies with relevant electrical safety and environmental directives listed in the specification.
What mechanical constraints should be observed during installation?
Maintain a minimum bend radius of 10x cable diameter and limit pull tension to the specified maximum to prevent conductor or insulation damage.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
相關連結
- Alpha Wire Ecogen Ecowire Series Blue 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 BL005
- Alpha Wire Ecogen Ecowire Series Grey 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 SL005
- Alpha Wire Ecogen Ecowire Series Green 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 GR005
- Alpha Wire Ecogen Ecowire Series Orange 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 OR005
- Alpha Wire Ecogen Ecowire Series Yellow 0.08 mm² Hook Up Wire 7 Modified Polyphenilether, 6710 YL005
- Alpha Wire Ecogen Ecowire Series Yellow 5.2 mm² Hook Up Wire 105 Modified Polyphenilether, 6719 YL005
- Alpha Wire Ecogen Ecowire Series Yellow 2.1 mm² Hook Up Wire 41 Modified Polyphenilether, 6717 YL005
- Alpha Wire Ecogen Ecowire Series Yellow 0.75 mm² Hook Up Wire 16 Modified Polyphenilether, 6715 YL005
