Honeywell Technologies AWM40000 Series Amplified Airflow Sensor for Dry Gas, 1000cm³/s Max

小計(1 件)*

TWD9,544.00

(不含稅)

TWD10,021.20

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 99 件從 2026年9月07日 起發貨
  • 加上 2 件從 2026年9月14日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD9,544.00

* 參考價格

RS庫存編號:
623-7927
Distrelec 貨號:
303-44-919
製造零件編號:
AWM43300V
製造商:
Honeywell
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Honeywell

Product Type

Airflow Sensor

Media Monitored

Dry Gas

Device Type

Amplified

Maximum Flow Rate

1000cm³/s

Housing Material

Plastic

Maximum Pressure

150psi

Maximum Supply Voltage

15V dc

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

85°C

Standards/Approvals

No

Series

AWM40000

不相容

COO (Country of Origin):
CN

Honeywell Amplified Airflow Sensor, 1000sccm, 8 to 15V DC - AWM4000 Series - AWM43300V


Measure the flow rate of Air in your system with this Airflow sensor from Honeywell. It's commonly used with medical equipment such as respirators and ventilators. For versatility, the device accurately senses flow rates between 0.1 and 1000sccm. Its plastic housing material makes it Durable and resistant to wear for long-lasting performance. For ease of installation, you can mount this sensor to a PCB.

Features & Benefits


• Fast typical response time of 1ms for almost immediate airflow readings

• Supply voltage range of 8 to 15V DC for use in low-voltage applications

Applications


• Heating and ventilation systems

• Robotics

• Automated assembly lines

• Pharmaceutical industry

Can I use this sensor in extreme temperatures?


Yes, thanks to its broad operating temperature range of -25°C to +85°C, this sensor is suitable for use in demanding environments.

Amplified Airflow Sensor AWM40000 Series


The AWM40000 Series mass flow sensor family is based on proven microbridge technology and includes both amplified signal conditioned devices and unamplified sensor only devices.;When using the unamplified devices (AWM42150VH and AWM42300V), the heater control circuit and the sensing bridge supply circuit are both required for operation per specification.

These two circuits are NOT on board the sensor and must be supplied in the application. The differential amplifier circuitry is useful in providing output gain and/or introducing voltage offsets to the sensor output.;The amplified devices (AWM43300V and AWM43600V) can be used to increase output gain and introduce voltage offsets.

The differential instrumentation amplifier circuitry, heater control circuitry and sensing bridge supply circuitry are all provided onboard the amplified sensors.

Features and Benefits


• Manifold mount/o-ring sealed;• Ceramic flow tube (non-outgassing), 0 to 1000 sccm;• High common mode pressure (150 psi ceramic flow tube only);• Operating temperature up to 125°C;• High stability at null and full scale

Product Application Information


• Damper control for heating, ventilation, and Air conditioning systems;• Gas analysers;• Low vacuum control;• Process control;• Medical respirators and ventilators;• Oxygen concentrators;• Leak detection equipment;• Vent hoods;• Anaesthesia control;• Gas metering;• Gas chromatography