Endress+Hauser DMA15 Series Flow Meter 0.05L/min to 35L/min, Male, G 1/2

小計(1 件)*

TWD18,989.00

(不含稅)

TWD19,938.45

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 加上 44 件從 2026年10月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD18,989.00

* 參考價格

RS庫存編號:
256-6150
Distrelec 貨號:
303-51-189
製造零件編號:
DMA15-AAAAA1
製造商:
Endress+Hauser
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Endress+Hauser

Product Type

Flow Meter

Connection Thread Size

G 1/2

Connection Gender

Male

Maximum Operating Temperature

60°C

Standards/Approvals

CE mark

Series

DMA15

Wetted Materials

316L Stainless Steel

Maximum Flow Rate

35L/min

Minimum Flow Rate

0.05L/min

COO (Country of Origin):
FR

Endress+Hauser DMA15 Series Flow Meter, 35 L/min Maximum Flow Rate, 60°C Maximum Operating Temperature - DMA15-AAAAA1


This flow meter measures liquid flow in process lines and provides precise monitoring across low to moderate flow rates. Constructed for corrosive and hygienic environments, it integrates a compact inline configuration with male G1/2 threaded connections for straightforward installation in existing piping. The unit is suitable for ambient applications where a CE‑marked device is required and where operation up to 60°C is needed.

Features and Benefits:


• 0.05-35 L/min range delivers accurate control for low to mid flows
• 316L wetted parts resist chemical and sanitary corrosion
• G1/2 male thread enables simple inline replacement
• CE marking ensures conformity with applicable EU directives
• 60°C maximum temperature supports warm process fluids

Applications


• Suitable for dosing and metering of liquid chemicals in production
• Used for sanitary liquid transfer in food and beverage lines
• Ideal for laboratory and pilot‑plant flow control tasks
• Can be used for recirculation monitoring in small process loops

What materials contact the fluid and why does that matter?


All wetted surfaces are stainless steel 316L, which provides compatibility with a wide range of aqueous and mildly aggressive liquids and supports hygienic cleaning where required.

How is the device connected into existing pipework?


The unit uses a male G1/2 threaded connection to mate directly with standard G‑threaded fittings and adaptors for inline installation.

What flow rates can be reliably measured?


The instrument covers flows from 0.05 L/min up to 35 L/min, accommodating both very low metering and higher throughput within the same device.

What environmental limit should be observed for fluid temperature?


The maximum operating fluid temperature is 60°C, which should be respected to maintain material integrity and measurement performance.