Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid, 0.2L/min Min, 150L/min Max
- RS庫存編號:
- 256-6154
- Distrelec 貨號:
- 303-51-193
- 製造零件編號:
- DMA25-AAAAA1
- 製造商:
- Endress+Hauser
小計(1 件)*
TWD26,557.00
(不含稅)
TWD27,884.85
(含稅)
訂單超過 $1,300.00 免費送貨
有庫存
- 加上 22 件從 2026年10月12日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD26,557.00 |
* 參考價格
- RS庫存編號:
- 256-6154
- Distrelec 貨號:
- 303-51-193
- 製造零件編號:
- DMA25-AAAAA1
- 製造商:
- Endress+Hauser
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Endress+Hauser | |
| Media Monitored | Liquid | |
| Product Type | Flow Meter | |
| Device Type | Electromagnetic Flowmeter | |
| Minimum Flow Rate | 0.2L/min | |
| Maximum Flow Rate | 150L/min | |
| Housing Material | 316L Stainless Steel | |
| Connection Type | Thread | |
| Maximum Pressure | 16bar | |
| Maximum Supply Voltage | 30V dc | |
| Minimum Media Temperature | -10°C | |
| IP Rating | IP65, IP67 | |
| Minimum Operating Temperature | -10°C | |
| Maximum Media Temperature | 70°C | |
| Maximum Operating Temperature | 60°C | |
| Series | DMA25 | |
| Standards/Approvals | CE mark | |
| 選取全部 | ||
|---|---|---|
品牌 Endress+Hauser | ||
Media Monitored Liquid | ||
Product Type Flow Meter | ||
Device Type Electromagnetic Flowmeter | ||
Minimum Flow Rate 0.2L/min | ||
Maximum Flow Rate 150L/min | ||
Housing Material 316L Stainless Steel | ||
Connection Type Thread | ||
Maximum Pressure 16bar | ||
Maximum Supply Voltage 30V dc | ||
Minimum Media Temperature -10°C | ||
IP Rating IP65, IP67 | ||
Minimum Operating Temperature -10°C | ||
Maximum Media Temperature 70°C | ||
Maximum Operating Temperature 60°C | ||
Series DMA25 | ||
Standards/Approvals CE mark | ||
- COO (Country of Origin):
- FR
Endress+Hauser DMA25 Series Flow Meter, 150 L/min Maximum Flow Rate, 16 Bar Maximum Pressure - DMA25-AAAAA1
This flow metre is an inline electromagnetic device designed to measure liquid flow in industrial settings. It operates across a broad flow range and is intended for use where robust construction and protection against ingress are required. The unit connects via threaded fittings and is suitable for environments that demand stainless-steel wetted parts and regulated electrical supply.
Features and Benefits:
• Electromagnetic measurement delivers high accuracy across range 0.2-150 L/min
• 316L stainless steel housing resists corrosion in process lines
• IP65 and IP67 protection enables washdown and temporary immersion
• Rated for media temperatures up to 70°C for warm-fluid handling
• 16 bar maximum pressure supports pressurised pipeline systems
• Accepts up to 30V DC supply for low-voltage industrial control
• 316L stainless steel housing resists corrosion in process lines
• IP65 and IP67 protection enables washdown and temporary immersion
• Rated for media temperatures up to 70°C for warm-fluid handling
• 16 bar maximum pressure supports pressurised pipeline systems
• Accepts up to 30V DC supply for low-voltage industrial control
Applications
• Suitable for water treatment dosing and monitoring loops
• Ideal for chemical feed control with corrosive liquids
• Used for flow verification in food and beverage processing lines
• Can be used for plant utilities metering in production facilities
• Used with control systems requiring threaded inline sensors
• Ideal for chemical feed control with corrosive liquids
• Used for flow verification in food and beverage processing lines
• Can be used for plant utilities metering in production facilities
• Used with control systems requiring threaded inline sensors
What connection type is used for installation in a pipework system?
Threaded connections allow direct inline mounting into existing threaded pipe fittings and adaptors.
How does the device perform in washdown or rainy conditions?
The enclosure meets IP65 and IP67 levels, protecting electronics during routine washdowns and brief submersion events.
What temperature range can the transmitter and measured media tolerate?
The instrument operates in ambient conditions down to -10°C while handling media temperatures as high as 70°C.
What maximum supply and pressure constraints must be observed?
The unit must not exceed a 30V DC supply and is qualified for process pressures up to 16 bar.
Which media is suitable for measurement with this technology?
The sensor is designed for conductive liquids, using electromagnetic principles to determine volumetric flow.
相關連結
- Endress+Hauser DMA25 Series Electromagnetic Flowmeter Flow Meter for Liquid 150L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 150L/min Max
- Endress+Hauser DMA20 Series Electromagnetic Flowmeter Flow Meter for Liquid 75L/min Max
- Endress+Hauser DMA50 Series Electromagnetic Flowmeter Flow Meter for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 750L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 35L/min Max
- Endress+Hauser DMA15 Series Electromagnetic Flowmeter IO-Link Module for Liquid 75L/min Max
- Cynergy3 FSU Series Flow Switch Flow Switch for Liquid 0.47L/min Max