HellermannTyton Connectivity HellermannTyton Category 6, 1 m Cat6 Ethernet Cable, Black RJ45 to Male RJ45 Male,

小計(1 件)*

TWD161.00

(不含稅)

TWD169.05

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 32 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD161.00

* 參考價格

RS庫存編號:
261-5393
製造零件編號:
RJ45NGB-1.0MBK
製造商:
HellermannTyton Connectivity
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

HellermannTyton Connectivity

Product Type

Ethernet Cable

Series

HellermannTyton Category 6

Cable Length

1m

LAN Category

Cat6

Shield Type

Unshielded

Connector Type A

RJ45

Connector Gender A

Male

Connector Gender B

Male

Connector Type B

RJ45

Jacket Colour

Black

Jacket Material

Low Smoke Zero Halogen

Standards/Approvals

ISO 11801:2002 (inc. Amend. A1 & A2), ANSI/TIA/EIA 568-C.2, IEC 61156-6, IEC 60332-1

COO (Country of Origin):
GB

HellermannTyton Connectivity HellermannTyton Category 6 Series Ethernet Cable, 1m Cable Length, Black Jacket - RJ45NGB-1.0MBK


This ethernet cable provides a one-metre link for high-speed LAN connections in structured network environments. It is an unshielded Cat6 patch lead with male-to-male RJ45 terminations and a low smoke zero halogen sheath, designed for horizontal, riser and campus installations where compact, flexible connectivity is required.

Features and Benefits:


• Supports Gigabit Ethernet and PoE delivery at 250MHz bandwidth
• Meets ISO 11801 and ANSI/TIA-568-C.2 performance requirements
• 26AWG stranded conductors reduce signal loss in patching scenarios
• Delay skew 45ns/100m optimises pair timing for balanced transmission
• LS0H jacket limits hazardous emissions in enclosed spaces
• Nominal velocity of propagation 65% improves timing predictability

Applications


• Suitable for connecting network switches to patch panels
• Ideal for linking desktops to wall outlets in offices
• Used with unshielded Category6 outlets and panels
• Can be used for PoE and PoE+ powered devices
• Suitable for short copper runs within data cabinets

What conductor and insulation construction does it use?


It uses 26AWG stranded copper conductors with HDPE insulation and four twisted pairs assembled into a single core.

What mechanical limits apply during installation?


Maximum tensile force during installation is 110N and minimum bend radius is 8x the outer diameter.

How does the cable behave electrically at 20°C?


DC loop resistance is 140Ω/km, insulation resistance is 5000MΩ/km and pair-to-ground capacitance unbalance is ≤330pF/100m.

Which environmental and fire properties are specified?


The sheath complies with IEC 60332-1 flammability standard and the operating temperature range is -20°C to +75°C.