HellermannTyton Connectivity Category 6A Cat6a Ethernet Cable Straight Male to Straight Male, 1 m, Green, S/FTP Low

小計(1 件)*

TWD226.00

(不含稅)

TWD237.30

(含稅)

Add to Basket
選擇或輸入數量
有庫存
  • 42 件準備從其他地點送貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位
每單位
1 +TWD226.00

* 參考價格

RS庫存編號:
261-5367
製造零件編號:
RJ45C6AGN-1.0M
製造商:
HellermannTyton Connectivity
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

HellermannTyton Connectivity

Series

Category 6A

Product Type

Ethernet Cable

Cable Length

1m

LAN Category

Cat6a

Shield Type

S/FTP

Connector Gender A

Male

Connector Type A

Straight

Connector Type B

Straight

Connector Gender B

Male

Jacket Colour

Green

Jacket Material

Low Smoke Zero Halogen

Standards/Approvals

IEC 61156-6, IEC 60332-1, BS EN 50173, ANSI/TIA/EIA 568-C.2, ISO 11801:2002 (inc. Amend. A1 & A2)

COO (Country of Origin):
CH

HellermannTyton Connectivity Category 6A Series Ethernet Cable, 1m Cable Length, Green Jacket - RJ45C6AGN-1.0M


This ethernet cable provides a shielded, male-to-male connection for high-speed network links in structured cabling environments. It is intended for short patching runs where enhanced noise rejection and fire-safety properties are required. The jacket is manufactured from a low-emission material and the cable meets international wiring and performance standards for enhanced 10 Gigabit-class installations.

Features and Benefits:


• S/FTP construction reduces external electromagnetic interference
• Meets IEC61156-6 for controlled transmission performance
• Complies with ISO11801 for channel transmission capability
• Straight RJ45 terminations enable standard patch-panel connectivity
• Low smoke zero halogen jacket lowers toxic fume output
• Male-to-male configuration supports direct patching between ports

Applications


• Suitable for data centre horizontal patching racks
• Ideal for office workspace network drops
• Used with 10GigE-enabled switches and routers
• Can be used for test and measurement link verification
• Used for connections in buildings requiring low-emission cabling

What shielding arrangement does it use and why is that important?


It uses a screened-foil over paired screening arrangement which limits crosstalk and improves immunity to external noise sources in electrically noisy environments.

Which connector orientation is provided for panel and device connections?


Both ends are terminated with straight male RJ45 plugs to allow connection to front-facing ports and conventional patch-panel sockets.

What jacket material characteristics affect building safety?


The outer sheath is a low smoke zero halogen compound that reduces smoke density and acidic gases during combustion, aiding occupant safety and equipment protection.

Which standards govern its electrical and fire-performance characteristics?


The cable conforms to internationally recognised telecom and wiring standards that specify transmission parameters and flame behaviour for structured cabling systems.

相關連結

第一時間了解我們的最新產品和優惠

電郵

您在訂閱此郵件時提供的個人信息將根據《隱私政策》進行處理。