Belden, 500 m Cat6a Cat6A Cable, Purple Unterminated to Unterminated Low Smoke Zero Halogen Sheath, F/FTP

小計(1 卷,共 500 米)*

TWD30,554.00

(不含稅)

TWD32,081.70

(含稅)

Add to Basket
選擇或輸入數量
暫時缺貨
  • 2026年7月22日 發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
每卷
每米*
1 +TWD30,554.00TWD61.108

* 參考價格

RS庫存編號:
631-593
製造零件編號:
10GXE01.07500
製造商:
Belden
透過選取一個或多個屬性來查找類似產品。
選取全部

品牌

Belden

Product Type

Cat6A Cable

LAN Category

Cat6a

Cable Length

500m

Shield Type

F/FTP

Connector Type A

Unterminated

Connector Type B

Unterminated

Jacket Colour

Purple

Jacket Material

Low Smoke Zero Halogen

Standards/Approvals

CE, EU, ISO/IEC 11801-1, IEC 62821

Voltage

72V

Series

10GXE01

COO (Country of Origin):
HU

Belden Power Cable Assembly, 500m Cable Length, Purple Jacket - 10GXE01.07500


This power cable assembly provides a long-reach, shielded supply solution for industrial and telecom installations where extended, low-emission cabling is required. It is supplied as a continuous, unterminated run in a highly visible purple jacket suitable for environments that need reduced toxic fume output. The construction supports medium-voltage distribution up to 72V and meets recognised international and regional standards for structured cabling and electrical installation.

Features & Benefits


• 500m length enables extended single-run installations
• F/FTP shielding reduces electromagnetic interference for sensitive equipment
• Low Smoke Zero Halogen jacket limits toxic emissions during combustion
• Purple sheath offers quick Visual identification in cable routes
• Conforms to EU and CE requirements for regional deployment

**Applications**


• Suitable for telecom room link cabling requiring shielded runs
• Ideal for data centre power routing with low-smoke requirements
• Used for factory automation where interference suppression is needed
• Can be used for electrical installations in public buildings with strict emission rules

How is the cable delivered for on-site termination?


It is supplied unterminated so technicians can perform bespoke connectorisation and length-specific preparations on site.

Which shielding arrangement is used to protect conductors?


The construction uses foil with individually screened pairs to provide comprehensive pair-level and overall screening.

What does the jacket material offer compared with standard PVC?


The jacket material is formulated to produce minimal smoke and no halogen acids if exposed to fire, improving occupant safety and equipment protection.

Which standards does the cable align with for structured cabling and safety?


It meets applicable international structured cabling and electrical installation standards specified for EU and global use.

相關連結