Fluke 1630-2 Earth Tester, 1.5 kΩ CAT III, CAT IV 1000V, 600 V
- RS庫存編號:
- 134-7342
- 製造零件編號:
- FLUKE-1630-2
- 製造商:
- Fluke
小計(1 件)*
TWD83,103.00
(不含稅)
TWD87,258.15
(含稅)
訂單超過 $1,300.00 免費送貨
製造商存貨
- 準備從 2026年10月01日 起發貨
**需要更多嗎?**輸入您需要的數量,然後按一下「查看送貨日期」以查詢更多庫存和送貨詳細資訊。
單位 | 每單位 |
|---|---|
| 1 + | TWD83,103.00 |
* 參考價格
- RS庫存編號:
- 134-7342
- 製造零件編號:
- FLUKE-1630-2
- 製造商:
- Fluke
規格
產品概覽和技術數據資料表
法例與合規
產品詳細資訊
透過選取一個或多個屬性來查找類似產品。
選取全部 | 屬性 | 值 |
|---|---|---|
| 品牌 | Fluke | |
| Product Type | Earth Tester | |
| Maximum Resistance Measurement | 1.5kΩ | |
| Accuracy | ±1.5 % of 0.02 Reading | |
| Measurement Type | Earth Ground Loop Resistance | |
| Display Type | LCD | |
| Battery Life | 15h | |
| Battery Type | AA Alkaline | |
| Power Source | Battery | |
| Weight | 880g | |
| Height | 283mm | |
| Includes | Safety Guide, Battery | |
| Length | 105mm | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC/EN | |
| Safety Category Level | CAT III, CAT IV | |
| Minimum Operating Temperature | -10°C | |
| Model Number | 1630-2 | |
| Width | 48mm | |
| Safety Category Voltage | 1000, 600V | |
| 選取全部 | ||
|---|---|---|
品牌 Fluke | ||
Product Type Earth Tester | ||
Maximum Resistance Measurement 1.5kΩ | ||
Accuracy ±1.5 % of 0.02 Reading | ||
Measurement Type Earth Ground Loop Resistance | ||
Display Type LCD | ||
Battery Life 15h | ||
Battery Type AA Alkaline | ||
Power Source Battery | ||
Weight 880g | ||
Height 283mm | ||
Includes Safety Guide, Battery | ||
Length 105mm | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC/EN | ||
Safety Category Level CAT III, CAT IV | ||
Minimum Operating Temperature -10°C | ||
Model Number 1630-2 | ||
Width 48mm | ||
Safety Category Voltage 1000, 600V | ||
豁免
- COO (Country of Origin):
- CN
Fluke Earth Tester, ±1.5% Accuracy, 15h Battery Life - FLUKE-1630-2
This earth tester is a clamp-style instrument for measuring earth/ground loop resistance and AC leakage current without disconnecting parallel grounds. It is intended for indoor and outdoor use where auxiliary stakes cannot be placed, enabling Rapid assessment of earthing components in paved areas, inside buildings or on power pylons. The instrument is battery-powered and pairs wirelessly with a mobile app to Record and store measurements and location data.
Features & Benefits
• Dual-clamp stakeless measurement eliminates auxiliary stakes and saves time
• ±1.5% accuracy on low-resistance ranges for precise loop readings
• True RMS leakage current measurement across a 40 Hz–1 kHz frequency range
• Stores a minimum of 32,760 logged readings for long-term data capture
• User-defined alarm thresholds enable Rapid pass/fail evaluation
• Band-pass filter reduces noise to improve leakage current clarity
• ±1.5% accuracy on low-resistance ranges for precise loop readings
• True RMS leakage current measurement across a 40 Hz–1 kHz frequency range
• Stores a minimum of 32,760 logged readings for long-term data capture
• User-defined alarm thresholds enable Rapid pass/fail evaluation
• Band-pass filter reduces noise to improve leakage current clarity
**Applications**
• Suitable for commissioning and troubleshooting multi-grounded earthing systems
• Ideal for maintenance checks on substations and overhead pylons
• Used for on-site verification of equipment earthing in paved facilities
• Can be used for leakage current surveys on electrical distribution networks
• Ideal for maintenance checks on substations and overhead pylons
• Used for on-site verification of equipment earthing in paved facilities
• Can be used for leakage current surveys on electrical distribution networks
What power source and runtime can I expect in the field?
It runs on four AA alkaline cells and delivers more than 15 hours of operation under typical ground resistance test conditions with the backlight and RF off.
How large a conductor can the clamp accept and what environmental protection exists?
The jaw accommodates conductors up to approximately 40mm diameter and meets IP30 ingress protection with the jaw closed.
How does the wireless system enhance Record keeping?
The wireless link transmits measured values, GPS coordinates and images to a Cloud service for association with assets and work orders, reducing manual transcription.
Which safety and measurement categories does it conform to?
It is rated to CAT IV 600V and CAT III 1000V for measurement applications and meets relevant IEC/EN standards.
What measurement resolution and overload indication are provided?
The display is a 9999-count LCD with a refresh rate of 4/s and indicates overload conditions with an OL message.
相關連結
- Fluke 1587 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke T6-1000 1000V CAT III, T6-1000
- Fluke T130 690V ac/dc Continuity Check CAT III, FLUKE T130
- Fluke T150 690V ac/dc Continuity Check CAT IV, FLUKE T150
- Fluke T110 690V ac/dc Continuity Check CAT III, FLUKE T110
- Fluke 1550C Insulation Tester 5000 V Max CAT III
- Fluke 1503 Insulation Tester 1000 V Max CAT III
- Fluke 1623 Earth Tester, 20 kΩ CAT II 300V